Read Sharp AR-150 (serv.man4) Service Manual online
2. Environmental
The environmental conditions for assuring the copy quality and the
machine operations are as follows:
machine operations are as follows:
(1) Normal operating condition
Temperature:20˚C~25
Humidity:65
Humidity:65
± 5%RH
(2) Acceptable operating condition
(3) Optical condition
(4) Supply storage condition
3. Production control number(lot No.)
identification
〈Developing cartridge〉
∗:Destination
Division
No.
EX Destination
A same pack
G
B same pack
H
Option Destination
A
P
B
Q
〈Drum cartridge〉
The label on the drum cartridge shows the date of production.
(SOCC production)
(SOCC production)
〈JAPAN production〉
Division
No.
Ex production
1
Option
2
Same pack
3
Humidity (RH)
85%
60%
20%
10˚C
30˚C
35˚C
Humidity (RH)
90%
60%
15%
–25˚C
30˚C
40˚C
Humidity (RH)
90%
20%
–5˚C
45˚C
Production month
Production day
Destination code
(Dealer, distributor, OEM, etc.)
Production place
(SOCC: Fixed to B.)
End digit of year
Version No.
Production month
Production day
Destination code
(Dealer, distributor, OEM, etc.)
Production place
(SOCC: Fixed to B.)
End digit of year
Version No.
X
0001
1
9
Ver.A
1
Production month
(1 - 9 = Jan. - Sep. 0 = Oct. X = Nov. Y = Dec.)
Serial number of month
Fixed to 1.
Pack division
(See table below)
End digit of year
Version No.
AR-F151
3 – 5