Read Sharp AL-840 (serv.man8) Service Manual online
S006/P001
Toner cartridge
S006/P002
Photoconductor cartridge
(1)
Open the operation unit.
(2)
Remove the toner cartridge (S006/P001).
(3)
Remove the photoconductor cartridge (S006/P002).
S006/P003
Developing bias electrode
S006/P004
Photoconductor earth electrode
S006/P005
Transfer roller
S006/P006
Transfer charger electrode
S006/P007
Developing bias electrode SP
S006/P008
Separation electrode
S006/P009
Main charger electrode SP
S006/P010
Earth electrode SP
(1)
Remove the rear cabinet S001/P001 .
(2)
Remove the front upper cabinet S001/P002 .
(3)
Remove the right cabinet S001/P003 .
(4)
Remove the left cabinet S001/P004 .
(5)
Remove the fan motor unit S010/P001 .
(6)
Remove the document table glass S001/P007 .
(7)
Remove the MCU (PCU) PWB unit S009/Ua002 .
(8)
Remove the power PWB unit S009/Ua001 .
(9)
Remove the scanner (reading) unit S004/Ua001 .
(10) Remove the gear and the screw, and remove the developing
bias electrode (S006/P003).
*
Cleaning
Use absolute alcohol to clean the developing bias electrode.
*
Troubles caused by improper work
1) Print image trouble (Insufficient density, streaks in the main
scanning direction)
2) Toner dispersion
(11) Remove the gear and the screw, and remove the photoconduc-
tor earth electrode (S006/P004).
*
Cleaning
Use absolute alcohol to clean the photoconductor earth electrode.
(12) Release the hook from the section A in the figure, and remove
the transfer roller (S006/P005).
*
Cleaning
Use absolute alcohol to clean the transfer roller.
*
Troubles caused by improper work
1) Print image detect (Insufficient density, improper density
balance, streaks in the main scanning direction)
(13) Release the hook, and remove the transfer charger electrode
(S006/P004).
S006/P003/CLN
S006/P004/CLN
S006/P005/CLN
A
9 – 22