(6) Fuse, thermostat
No.
Parts
MODEL
Note
Code
Name
Form
Form
Specification
Function/operation
1
F603
Power unit fuse
Mini
Normal
5A 125V
Protects the power unit primary side circuit
against an overcurrent.
100V series
3.15A 250V
20V series
2
F601
Power unit fuse
Mini
Normal
10A 125V
Protects the power unit primary side circuit
against an over.
100V series
5A 250V
200V series
3
Temperature fuse 1
(Fusing section)
Mold
Temperature
fuse
132°C 250V
10A
Assures safety in overheating.
4
Temperature fuse 2
(Fusing section)
Mold
Temperature
fuse
187°C 125V
1.5A
Assures safety in overheating.
(7) Lamp
 
 
 
No.
Parts
Model
Note
Code
Name
Type
Function/operation
Specification
1
SL
Scanner lamp
Cool cathode ray tube (Xenon
lamp)
Light source for scanning
(reading)
Common
2
HL
Heater lamp
Halogen lamp
Heating for the heat roller.
100V 500W
10V series
120V 500W
120V series
230V 500W
200V series
3)
4)
2) F601
1) F603
1) SL
2) HL
5 – 18
Page of 23
Display