AL-840 (serv.man2). AL800 840 Specifications - Sharp Copying Equipment Specification (repair manual). Page 7

Read Sharp AL-840 (serv.man2) Specification online

M. Operating voltage/power consumption
Sub-
sidiaries
Power
supply
voltage/
 frequency
Power consumption
Power
save
mode
Ready
mode
Power
shut-
down
mode
Average
(during
printing)
Max.
120V
50/60Hz
29 Wh/h
55 Wh/h
17 Wh/h
170 Wh/h
600 W
220–240V
50/60Hz
35 Wh/h
64 Wh/h
19 Wh/h
175 Wh/h
600 W
(Within Rated voltage 
±
 10% and Rated frequency 
±
 2%)
N. Safety/environmental standard
(1) Safety/environmental standard
Item
Standard name
Country
Safety standard
SEMKO
Sweden
NEMKO
Norway
DEKRA (GS MARK)
Germany
BSI
U.K
CUL UL
USA/Canada
FDA
USA
Radio wave noise
standard
CE MARK
Europe
C-TICK
Australia
FCC
USA
Energy standard
ENERGY STAR
World wide
(Printer only)
Environmental
standard
(2) Ozon level
Very low (unmeasurable level)
(3) Noise level
Noise mode
Individual
Operating
mode
Ready mode
Power
shut-down
mode
Sound power
level
66
40
0 dB
Sound
pressure level
54.8 dB
0 dB
O. Ambient conditions
(1) Occupied area
Main unit
460 
×
 650 mm (18.2 
×
 29.53 in.)
(2) Operating conditions
(3) Storage conditions (packed in the packing material)
(4) Transport condition (packed in the packing material)
(5) Atmospheric pressure
595 mmHg or above
(6) Standard condition
20 to 25°C  65
±
5% RH, Rating for different countries
10˚C
35˚C
85%
20%
30˚C, 85%
35˚C, 60%
Humidity
Temperature
RH
–10˚C
50˚C
90%
10%
40˚C, 90%
50˚C, 60%
Humidity
Temperature
RH
Machine
–10˚C
40˚C
90%
10%
40˚C, 90%
Humidity
Temperature
RH
Supply
25˚C
40˚C
90%
15%
30˚C, 90%
40˚C, 60%
Humidity
Temperature
RH
Machine
10˚C
40˚C
90%
10%
40˚C, 90%
Humidity
Temperature
RH
Supply
2 – 7