Cleaning
Use absolute alcohol to clean the scanner lamp light quantity
sensor as shown below.
*
Troubles caused by improper work
1) Improper copy density 
(8)
Loosen the wire fixing screw of the scanner unit A (S004/Ua001/
Ub001), and remove the wire.
(9)
Remove the screw, and remove the shaft.
(10) Remove the connector, cut the binding band, and remove the
scanner unit A (S004/Ua001/Ub001).
(11) Remove the No. 1 mirror (S004/Ua001/Ub001/P002).
S004/Ua001/
Ub001/P003/CLN
S004/Ua001/Ub001
S004/Ua001/Ub001
9 – 17