Troubles caused by improper work
1) Copy (print) defective
(Insufficient density, background copy, dirt, etc.)
(Ghost)
2) The copy density cannot be adjusted with SIM 46-1.
3) Photoconductor damage
*
After-work
JOB No.
Content
ADJ M1
Copy density adjustment
*
Necessary tools
Name
Digital multi-meter/High voltage probe
Parts code/Price rank
—
Note
Internal impedance of 1000M
Ω
or
above, effective value measurement
(Recommendable unit: FLUKE
87/FLUKE 80K-40)
(Recommendable unit: FLUKE
87/FLUKE 80K-40)
*
Note
1) Use a digital multi-meter (effective value meter, internal im-
pedance of 1000M
Ω
or above).
Connect the capacitor and the diode to the tip of the digital multi-
meter for measurement. If the above condition are not satisfied,
the proper measurement of voltage cannot be made.
meter for measurement. If the above condition are not satisfied,
the proper measurement of voltage cannot be made.
2) Since a high voltage is outputted, be careful of electric shock.
CHI M1
Image process (high votlage) power
check
check
*
Specified values
Range (MIN)
+3200V
Range (MAX)
+3700V
Standard value
+3500V
Default
+3500V
*
Progarm used
Test command (Simulation)
MODE
Normal
MAIN CODE
8
SUB CODE
2
*
Execution condition (time)
Enforcement
time
time
JOB No
Content
S 009/Ua004
When replacing the high
voltage/motor drive PWB unit
voltage/motor drive PWB unit
Cycle
—
Condition
1) Print (copy) density is too
dark or too light.
Though copy density
adjustment is executed
with the Test command
(simulation) 46-1,
satisfactory denstiy cannot
be obtained.
Though copy density
adjustment is executed
with the Test command
(simulation) 46-1,
satisfactory denstiy cannot
be obtained.
2) Ghost is generated.
*
Work content
1) Connect between the power PWB and the PCU PWB, the high
voltage/motor drive PWB unit and the operation unit with har-
nesses.
nesses.
2) Manually turn on the cover switch and turn on the power.
3) Execute SIM 8-2.
(The transfer charger voltage is outputted.)
4) Measure the transfer charger voltage (D805) with the digital multi-
meter (effective value meter).
Check that the output voltage is +3200
∼
+3700V. If it is not in the
range, replace the high voltage/motor drive PWB unit.