AL-2020 (serv.man2). Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 79

Read Sharp AL-2020 (serv.man2) Service Manual online

AL-2040  SIMULATION, TROUBLE CODES  10 - 19
L1
00
Content Feeding is not completed within the 
specified time after starting feeding. (The 
scan head locking switch is locked)
Detail
The white area and the black marking on 
the shading plate are used to obtain the 
difference in the CCD level values for 
judgment of lock. When the difference in 
the levels of which and black is small, it is 
judged that the black mark could not be 
scanned by lock and the trouble code “L1” 
is displayed.
Cause
The scan head is locked by the lock switch.
Mirror unit abnormality
The scanner wire is disconnected.
The origin detection sensor abnormality
Mirror motor harness abnormality
Check 
and 
remedy
Check to confirm that the scan head lock 
switch is released.
Use SIM 1-1 to check the mirror 
reciprocating operations.
When the mirror does not feed.
Check for disconnection of the scanner 
wire.
Check the harness and the connector 
between the mirror motor and the MCU 
PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home 
position sensor.
L3
00
Content Scanner return trouble
Detail
When the mirror base is returned for the 
specified time (6 sec) in mirror initializing 
after turning on the power, the mirror home 
position sensor (MHPS) does not turn ON. 
Or when the mirror base is returned for the 
specified time (about 6 sec) after start of 
copy return, the mirror home position 
sensor (MHPS) does not turn ON.
Cause
Mirror unit abnormality
Scanner wire disconnection
Origin detection sensor abnormality
Mirror motor harness abnormality
Check 
and 
remedy
Use SIM 1-1 to check the mirror 
reciprocating operations.
When the mirror does not return.
Check for disconnection of the scanner 
wire.
Check the harness and the connector 
between the mirror motor and the MCU 
PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home 
position sensor.
Main 
code
Sub 
code
Details of trouble
L4
01
Content Main motor lock detection
Detail
When the main motor encoder pulse is not 
detected for 100 msec.
Cause
Main motor unit abnormality
Improper connection or disconnection the 
main motor and the harness.
MCU PWB abnormality
Check 
and 
remedy
Use SIM 25-01 to check the main motor 
operations.
Check connection of the main motor 
harness/connector.
Replace the main motor.
Replace the MCU PWB.
32
Content Exhaust fan motor lock detection trouble
Detail
The error detection is started after 2 sec 
from starting rotation of the exhaust fan 
motor.
1) The continuous rotation state of 250ms 
is not detected for 1 sec after starting 
detection.
2) When the lock sensor (in the exhaust 
fan) detects the HIGH level (unstable) 
after detection the lock state (stable 
state).
Cause
Exhaust fan motor connector connection 
trouble
Exhaust fan motor trouble
MCU PWB trouble
Check 
and 
remedy
Exhaust fan motor connector connection 
check
Exhaust fan motor replacement
Replace the MCU PWB.
L6
10
Content Polygon motor lock detection
Detail
The lock signal (specified rpm signal) does 
not return within a certain time (about 20 
sec) from starting the polygon motor 
rotation.
Cause
Polygon motor unit abnormality
Improper connection or disconnection of 
the polygon motor and the harness.
MCU PWB abnormality
Check 
and 
remedy
Use SIM 61-1 to check the polygon motor 
operations.
Check connection of the polygon motor 
harness/connector.
Replace the polygon motor.
Replace the MCU PWB.
U2
04
Content EEPROM read/write error (Serial 
communication error)
Detail
EEPROM access process error
Cause
EEPROM abnormality
Check 
and 
remedy
Check that the EEPROM is properly set.
Use SIM 16 to cancel the trouble.
Replace the MCU PWB.
11
Content Counter check sum error (EEPROM)
Detail
Check sum error of the counter area in the 
EEPROM
Cause
EEPROM abnormality
Check 
and 
remedy
Check that the EEPROM is properly set.
Use SIM 16 to cancel the trouble.
Replace the MCU PWB.