AL-1622 (serv.man13). Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp AL-1622 (serv.man13) Service Manual online

AL-1611/AL-1622
TROUBLE CODE LIST
10 – 5
L3
00
Cause
Mirror unit 
Mirror home position sensor defect 
MCU PWB defect Scanner wire discon-
nection
Check and 
remedy
Check the scanning operation with SIM 
1-1.
L4
01
Content
Main motor lock
Detail
The main motor encoder pulse is not 
detected for 400msec.
Cause
Main motor defect 
Harness disconnection between the 
MCU PWB and the main motor. 
Control circuit failure
Check and 
remedy
Check the main motor operation with 
SIM 25-1. 
Check the harness and the connector 
between the MCU PWB and the main 
motor.
10
Content
Job separator motor trouble
Details
When the home is not detected within 
2.5 sec after the job separator tray starts 
to move upwards.
Cause
The job separator upper limit detection 
sensor is defective. 
The job separator motor is defective. 
The job separator motor periphery circuit 
is defective. The condition of the MCU 
PWB JP5 is wrong.
Check and 
countermea-
sure
Check the job separator operation by 
means of SIM3-2 and 4. 
Check the harnesses and connectors. 
Check whether the condition of the MCU 
PWB JP5 is correct.
L6
10
Content
Polygon motor lock
Detail
The lock signal (the specified rotation 
speed signal) is not supplied within the 
specified time (about 6 sec) after starting 
the polygon motor rotation.
Cause
LSU connector disconnection or harness 
disconnection in the LSU.
Check and 
remedy
Check the operation of the polygon 
motor with SIM 25-10. 
Check the harness and the connector 
connection. LSU replacement
L8
01
Content
Zero cross pulse (FW) trouble
Detail
Zero cross pulse width is shifted by 55Hz 
m
 10% or more.
Cause
MCU PWB defect Power supply unit 
breakdown
Check and 
remedy
Check the harness and the connector. 
MCU PWB replacement Power supply 
unit replacement
U2
04
Content
EEPROM serial communication error
Detail
Error in communication with EEPROM
Cause
EEPROM failure 
Installation of uninitialized EEPROM 
MCU PWB EERPOM access circuit fail-
ure
Check and 
remedy
Check that the EEPROM is properly set. 
To prevent against loss of counter/
adjustment values, record the values 
with simulation. 
U2 trouble cancel with SIM 16 MCU 
PWB replacement
Main
code
Sub
code
Detail of trouble
U2
11
Content
Counter check sum error
Detail
Counter check sum value stored in the 
EEPROM is abnormal.
Cause
EEPROM failure 
Control circuit hung up by noises 
MCU PWB EEPROM access circuit 
defect
Check and 
remedy
Check that the EEPROM is properly set.  
To prevent against loss of counter/
adjustment values, record the values 
with simulation. 
U2 trouble cancel with SIM 16 MCU 
PWB replacement
12
Content
Adjustment value check sum error 
(EEPROM)
Detail
Adjustment value data area check sum 
error
Cause
EEPROM failure 
Control circuit hung up by noises 
MCU PWB EEPROM access circuit fail-
ure
Check and 
remedy
Check that the EEPROM is properly set. 
To prevent against loss of counter/
adjustment values, record the values 
with simulation. 
U2 trouble cancel with SIM 16 MCU 
PWB replacement
40
Content
CRUM communication error
Detail
Toner cartridge CRUM data read error
Cause
A toner cartridge of a different destina-
tion is installed. 
EEPROM trouble 
Check the destination setup. 
Toner cartridge CRUM PWB trouble 
MCU PWB trouble 
CRUM connector disconnection
Check and 
remedy
Install a specified toner cartridge. 
Check the SIM 26-6 setup. 
Replace the EEPROM. Replace the 
toner cartridge. 
Replace the MCU PWB. 
Check connection of the CRUM connec-
tor. 
Execute SIM 16.
U3
29
Content
Mirror base home position error
Detail
Home position is not detected when 
starting mirror base shift.
Cause
Mirror unit defect 
Mirror home position sensor defect 
MCU PWB decfect 
Scanner wire disconnection
Check and 
remedy
Check the scanning operation with SIM 
1-1.
U9
00
Content
Communication trouble between MCU 
and OPE (OPE detection)
Detail
Communication setup error, framing, 
parity, protocol error
Cause
Operation control PWB connector dis-
connection 
Operation control PWB MCU PWB har-
ness failure
Check and 
remedy
Check the connectors and harness of 
the operation control PWB and the MCU 
PWB. 
Check grounding of the machine. 
Check the ROM of the operation control 
PWB.
Main
code
Sub
code
Detail of trouble
Page of 6