AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 7
8
01
Developing bias output 
(DVLP BIAS SET.)
[Function]
When [OK/START] key is pressed, the developing bias signal is turned ON for 30sec.
When, however, an actual output value is measured, use test command 25-01.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
02
Main charger output (Grid 
HIGH) (MHV(H) SET.)
[Function]
When [OK/START] key is pressed, the main charger is outputted for 30sec in the grid voltage HIGH
move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
03
Main charger output (Grid 
LOW) (MHV(L) SET.)
[Function]
When [OK/START] key is pressed, the main charger is outputted for 30sec in the grid voltage LOW
move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
06
Transfer charger output 
(THV SET.)
[Function]
When [OK/START] key is pressed, the transfer charger is outputted for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
9
01
Duplex motor normal 
rotation check (DPLX ROT.)
[Function]
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for
30sec. 
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
02
Duplex motor reverse 
rotation check (DPLX 
ROT.REV.)
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation]
04
Duplex motor rotating speed 
adjustment (DPLX 
ROT.SPEED)
[Function]
When this Test Command is executed, the currently set value is displayed.
Enter the adjustment value with [10KEY] and press [START] key. The entered value is stored and the 
machine goes into the sub code entry standby mode. The greater the set value is, the higher the 
speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 6)
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
08-01 DVLP BIAS SET.
EXECUTING...
1) Initial display
08-02 MHV(H) SET.
EXECUTING...
1) Initial display
08-03 MHV(L) SET.
EXECUTING...
1) Initial display
08-03 THV SET.
EXECUTING...
1) Initial display
09-01 DPLX ROT.
EXECUTING...
1) Initial display
09-02 DPLX ROT.REV.
EXECUTING...
1) Initial display
2) [10KEY]
3) [OK/START]
09-04 DPLX ROT.SPEED
            6( 1-13)
09-04 DPLX ROT.SPEED
            7( 1-13)
09-04 DPLX ROT.SPEED
            7( 1-13)