Auto Clear
Pre-Heat Timer Setting
Auto shut off time
Stream feed (SPF models)
Auto shut off setting
Auto/Manual mode resolution set up
The User Programs allow the parameters of certain functions to be set, reset,
changed or cancelled as desired.
User Program Modes Entry
Press and hold the right and left EXPOSURE ADJUSTMENT KEYS
simultaneously for 5 seconds.
The Drum, Jam, & Toner lamps will flash at the same time and
“- -“ will show in the copy quantity display.
Select the function code with the copy quantity keys.
The following chart shows which programs can now be selected.  Enter the function
name value followed by the set code value.
Function Name
Function Code
Set Code
1
0 (Cancel)
1 (30 sec)
        *2 (60 sec)
3 (90 sec)
Auto Clear
  4 (120 sec)
2
*0 (30 sec)
1 (60 sec)
Pre-heat
2 (90 sec)
3
0  (2  min)
*1 (5 min)
2 (15 min)
3 (30 min)
4 (60 min)
Auto shut off
5 (120 min)
4 (SPF only)
0 (Cancel)
 Stream feeding
*1 (Setting)
Auto Shut Off Setting
5
0 (Cancel)
*1 (Setting)
Auto/Manual mode resolution set up
6
*0 (300dpi)
1 (600 dpi)
      * Factory setting
1) 
Auto clear-Elapsed time between job completion and the machine returning to standard conditions.
2) 
Pre heat  – Elapsed time between job completion and the machine entering pre-heat mode.
3) Auto 
shut-off 
– Elapsed time between job completion and the machine switching to Shut Down.
4) Stream 
feed 
– Selection or de-selection of stream feeding mode when using the document feeder
5) 
Auto shut-off setting – Selection or de-selection of auto shut off mode  shown in 3)
6) 
Auto/Manual mode resolution set up – Used to set the resolution in the auto/manual mode