AL-1457D. Handy guide - Sharp Copying Equipment Handy Guide. Page 14

Read Sharp AL-1457D Handy Guide online

USER PROGRAM
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
14
VERSION 1
JANUARY 2004
USER PROGRAM
Auto Clear
Pre-Heat Timer Setting
Auto Power Shut Off Time
Stream feed (SPF models)
Auto Shut Off Setting
Auto / Manual Mode Resolution Set Up
The User Programs allow the parameters of certain functions to be set, reset, changed or
cancelled as desired.
User Program Modes Entry
Press and hold the right and left EXPOSURE ADJUSTMENT KEYS
simultaneously for 5 seconds.
The Drum, Jam, Toner & Maintenance lamps will flash at the same time and
“- -“ will show in the copy quantity display.
The following chart shows which programs can now be selected.  Enter the function name
value followed by the set code value.
Function Name
Function Code
Set Code
Auto Clear
1
0  (Cancel)
1  (10 sec)
2  (30 sec)
*3 (60 sec)
4  (90 sec)
5  (120 sec)
Pre Heat
2
*0 (30 sec)
1  (60 sec)
2  (90 sec)
Auto Shut Off
3
0  (2 min)
*1 (5 min)
2  (15 min)
3  (30 min)
4  (60 min)
5  (120 min)
Stream Feeding
4 (SPF only)
0  (Cancel)
*1 (Setting
Auto Shut Off Setting
5
0  (Cancel)
*1 (Setting)
Auto/Manual Mode Resolution Set Up
6
*0 (300dpi)
1  (600dpi)
  * Factory Setting
1) 
Auto clear-Elapsed time between job completion and the machine returning to standard conditions.
2) 
Pre heat mode setting – Elapsed time between job completion and the machine entering pre-heat mode.
3) 
Auto shutoff – Elapsed time between job completion and the machine switching to Shut Down.
4) 
Stream feed – Selection or de-selection of stream feeding mode when using the document feeder
5) 
Auto shut-off setting – Selection or de-selection of auto shut off mode  shown in 3)