AL-1457 (serv.man51). 1 Standardising the roller R (pickup roller) in the manual paper feeding section. 2 Changing to lead-free operation PWB and IF PWB. 3 Changing the high voltage PWB to comply with RoHS. - Sharp Copying Equipment Technical Bulletin (repair manual)

al-1457 (serv.man51) technical bulletin
Model
AL-1457 (serv.man51)
Pages
3 Few pages! See other manuals at the bottom of the first or last page.
Size
69.58 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / 1 Standardising the roller R (pickup roller) in the manual paper feeding section. 2 Changing to lead-free operation PWB and IF PWB. 3 Changing the high voltage PWB to comply with RoHS.
File
al-1457-sm51.pdf
Date

Read Sharp AL-1457 (serv.man51) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
DCE564
1.  Standardising the roller R (pick up roller) in the manual paper feeding section.
1. Model Name
AL1220/1457/1520/1551/1553/1555/
2. General
The roller R for the above models has been changed to standardise with other models.
3. Content
Current parts
New parts
No
Model
name
Version
P/G
No.
Parts code
Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Content
*
1
18 -5
*
2
19 -5
1
*5
ALL
23 -5
NROLP1008FCZZ NROLR0105QSZZ
AR
Roller R
'04/12
1
Change
<Interchange>
1. Interchangeable.
4. Not Interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related
parts in use.
3. Current type cannot be used in place of new
type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones
for maintaining the safety and performance of the set.
*1 = AL1220/
*2 = AL1457/1553
*5 = AL1551
1.  Standardising of the roller R (pick up roller) in the
manual paper feeding section.
2.  Changing to lead-free operation PWB and IF PWB.
3.  Changing the high voltage PWB to comply with
RoHS.
TECHNICAL BULLETIN
Date:
21
st
 June 2005
Model: 
AL1045/1217/1220/
1255/1456/1457/1520/
1551/1553/1555
Ref.:
002
Colour: 
White
Page:
1 of 3
Sharp Electronics (UK) Ltd., Technical Services Group
DCE564
4. Action
From the production in December 2004.
2.  Changing to lead-free operation PWB and IF PWB.
1. Model Name
AL1045/1217/1255/1456/1457/1555
2. General
Since the operation PWB and the IF PWB for the above models have been changed to
lead-free type, the parts code have also changed.
3. Content
Current parts
New parts
No
Model
name
Versi
on
P/G
No.
Parts code
Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
chang
e-
ability
Content
AL1217
25 -901
CPWBF0113QSE1
CPWBF0113QSG1
AL1255
8-8
CPWBF0113QSE2
CPWBF0113QSG2
AL1555
8-8
CPWBF0113QSE3
CPWBF0113QSG3
AL1456
8-8
CPWBF0113QSE4
CPWBF0113QSG4
AL1045
8-8
CPWBF0113QSE6
CPWBF0113QSG6
AL1457
6-8
CPWBF0113QSE&
CPWBF0113QSG7
BB
Operation PWB
*2
13-5
27-901
1
*3
ALL
15-5
31-901
CPWBF0114QSE1
CPWBF0114QSF1
BA
IF PWB
04/12
1
<Interchange>
1. Interchangeable.
4. Not Interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related
parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones
for maintaining the safety and performance of the set.
*2 = AL1217/1457
*3 = AL1045/1555
Sharp Electronics (UK) Ltd., Technical Services Group
DCE564
 3  /  6  /  8  -No.8 Operation PWB unit            13 / 15 -No.5, 39 -40 IF PWB unit
4. Action
From the production in December 2004
3.  Changing the high voltage PWB to comply with RoHS.
1. Mode Name
AL1217/1457/1553/1045/1255/1555
2. General
The high voltage PWB for the above models has been changed to comply with RoHS and
to standardise with other models.
3. Content
Current parts
New parts
No
Model
name
Version
P/G
No.
Parts code
Parts code
Price
rank
Parts name
Effec-
tive
time
Inter-
change-
ability
Conte
nt
1
*3
ALL
13 -6 RDENC0007QSZZ
RDENC0013QS11
BG
High voltage
PWB
'05/5
1
<Interchange>
1. Interchangeable.
4. Not Interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related
parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones
for maintaining the safety and performance of the set.
*3 = AL1045/1255/1456/1555
No.6 High voltage PWB unit
4. Action
From the production in May 2005 (SOCC/Japan production)
From the production in June 2005 (SMF production)
Page of 3
Display

Download Sharp AL-1457 (serv.man51) Technical Bulletin

Here you can read online and download Sharp AL-1457 (serv.man51) Technical Bulletin in PDF. AL-1457 (serv.man51) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AL-1457 (serv.man51) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.