AL-1456 (serv.man12). Simulation and trouble codes - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp AL-1456 (serv.man12) Service Manual online

AL-1555 SIMULATION, TROUBLE CODES 10 - 7
26
42
Transfer ON timing control setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different from the following 
ones, the default time is automatically set.)
43
Side void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the side void amount is displayed.
2. Enter the code number and press the start key. The setting is changed.
44
SPF document rear edge read setup + Fax document rear edge scan setup.
When this simulation is executed, the currently set code number is displayed. Enter the desired code number and press the START 
key, and the display will be changed. The document rear edge scanning area in SPF reduction (less than 100%) copy is changed.
The code number is changeable in the range of 0 – 8.
The default value is 4, and 2 mm of the document rear edge is cut.
When the value is changed by 1, the area is changed by 1 mm.
62
Energy-save mode copy lamp setup
Used to set half-ON (50%)/OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup.
63
Fan control select setup
Used to set the cooling fan operation mode.
When this simulation is executed, the current setup of the code number is displayed. Enter the code number and press the PRINT 
switch to enable the setup.
Main 
code
Sub 
code
Content
Code number
Setting
0
Default (330 msec)
1
– 40 msec
2
– 30 msec
3
– 20 msec
4
– 10 msec
5
Default (330 msec)
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
Code number
Setting
0
0  mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm * Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.0 mm
Code number
Setup
0
Copy lamp half-ON (50%) * Default
1
Copy lamp OFF
Code number
Setup
1
1-speed fan control
2
2-speed fan control * Default when starting mass production
Page of 15