MATERIAL  SAFETY  DATA  SHEET 
Page: 3/4
 
Date Revised: Jul. 31. 2002
 
Date Issued  : Jun.   1. 1998 
MSDS No. F-30831 
9.PHYSICAL AND CHEMICAL PROPERTIES 
Appearance 
Physical State : Solid 
Form : Powder 
Color : Black 
Odor : odorless 
Ph : Not applicable 
Boiling / Melting Point 
: Not applicable 
Flash Point(°C) 
: Not applicable 
lgnition Point(°C ) 
: No data 
Explosion Properties 
: No data 
Density(g/cm³) : 5.4   (bulk density : 2.09) 
Solubility in Water 
: Negligible 
 
10.STABILITY AND REACTIVITY 
Stability : Stable 
Hazardous Reactions 
: Dust explosion, like most finely divided organic powders. 
Conditions to Avoid 
: Electric discharge, throwing into fire. 
Materials to Avoid 
: Oxidizing Materials 
Hazardous Decomposition Products 
: CO, CO
2
 and NO
X
 
Further Information 
: None 
 
11.TOXICOLOGICAL INFORMATION 
Acute Toxicity 
Ingestion(oral) : 
LD
50
 > 2000mg/kg (Rats) 
Inhalation : 
No 
data 
Dermal                     : LD
50
>2000mg/kg(Rats) 
Eye irritation 
: Not an irritant (Rabbits) 
Skin irritation 
: Not an irritant (Rabbits) 
Skin sensitizer 
: No sensitization 
Mutagenicity : Negative (Ames Test) 
Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen).
This classification is given to chemicals for which there is inadequate human evidence, but sufficient
animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the
development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels
that induce particle overload of the lung. Studies performed in animal models other than rats did not
show any association between carbon black and lung tumors. Moreover, a two-year cancer bioassay
using a typical toner preparation containing carbon black demonstrated no association between toner
exposure and tumor development in rats. 
Chronic Effect 
: In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate degree of lung
fibrosis was observed in 92% of the rats in the high concentration (16mg/m
3
) exposure group, and a
minimal to mild degree of fibrosis was noted in 22% of the animals in the middle (4mg/m
3
) exposure
group, but no pulmonary change was reported in the lowest (1mg/m
3
) exposure group, the most relevant
level to potential human exposures. 
 
12.ECOLOGICAL INFORMATION 
No data are available.
 
 