PN-Y475 - Sharp Monitor Service Manual (repair manual). Page 107

Read Sharp PN-Y475 Service Manual online

PN-Y325/Y425/Y475/Y555   HARDWARE DESCRIPTIONS
      9 - 1 
 
CHAPTER 9. HARDWARE DESCRIPTIONS 
 
1. OVERVIEW                                                                               
1-1. SYSTEM COMPONENT 
This monitor consists of LCD module, Main PWB, Speed relay PWB, T-CON PWB, LED/KEY PWB, Power PWB and LED Driver PWB. 
1-2. LCD UNIT 
No 
Items 
PN-Y325 
PN-Y425 
PN-Y475 
PN-Y555 
1 LCD 
32” 
Class 
Wide 
LCD(AUO) 42” 
Class 
Wide 
LCD(LG) 47” 
Class 
Wide 
LCD(LG) 55” 
Class 
Wide 
LCD(LG) 
Display size 
32 inch (80.1cm diagonal) 
42 inch (106.7cm diagonal) 
47 inch (119.3cm diagonal) 
55 inch (138.8cm diagonal) 
Max resolution 
1920 x 1080 
Max colors 
1677 million color 
10.6 billion color 
Pixel 
pitch 
0.364 0.485 0.542 0.630 
6 Max 
brightness 
350cd/㎡ 450cd/㎡ 
7 Contrast 
ratio 
3000:1 1500:1 
Viewing angle 
Up, down, left and right 178° 
Display screen size 
698.4 X 392.9 mm 
930.2 X 523.3mm 
1039.7 X 584.8mm 
1209.6 X 680.4mm 
10 
Panel response speed 
8ms 
12ms 
11 Backlight 
Edge 
LED 
12 
Backlight life 
50,000(landscape, horizontal installation) 
13 Screen 
uniformity 
70% 
 
1-3. Main PWB 
Main PWB controls the audio and video input/output. 
The menu for the monitor and the set value of PICTURE in process mode is stored to IC3804. (Refer to the “4. PARTS LAYOUT“ for 
location.) 
 
1-4. Temperature sensor 
Temperature sensor is mounted to U4251 on Main PWB. (Refer to the “4. PARTS LAYOUT“ for location.) 
Backlight brightness is decreased once abnormal temperature is detected. 
In addition, the monitor enters standby state once the temperature is further increased. 
*The power lamp blinks in red and green alternately once the abnormal temperature is detected. 
 