Read Sharp PN-Y325 Service Manual online
PN-Y325/Y425/Y475/Y555 INSTALLATION, ADJUSTMENT, SETTING 2 - 12
[RS-232C command table]
How to read the command table
Command : Command field.
Direction
: W When the “Parameter” is set in the parameter field, the command functions as describedunder a “Control/Response
Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+” (repeater control) in
the parameter field.
Parameter : Parameter field.
Reply
: Response (Returned value)
*
: “
○” indicates a command which can be used in power standby mode.
“–” indicates a command which cannot be used in power standby mode.
(When STANDBY MODE is STANDARD. When set to LOW POWER, RS-232C commands cannot be used.)
#
: Can be saved of the set value for Display Installation Tool.
Power control/Input mode selection
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
POWER CONTROL
POWR(#)
W
0
Switches to standby mode.
○
1
Returns from standby mode.
R
0
Standby mode
1
Normal mode
2
Input signal waiting mode
INPUT MODE SELECTION
INPS(#)
W
0
Toggle change for input mode.
1
DVI-D
2
D-SUB[RGB]
3
D-SUB[COMPONENT]
4
D-SUB[VIDEO]
9
HDMI[AV]
10
HDMI[PC]
11
USB
R
1
DVI-D
2
D-SUB[RGB]
3
D-SUB[COMPONENT]
4
D-SUB[VIDEO]
9
HDMI[AV]
10
HDMI[PC]
11
USB
SCREEN menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
POSITIONING
POSITION OF THE
LONGEST
DIRECTION
HPOS
WR
0 ~ 100
0 ~ 100
When the input mode is D-SUB.
―
POSITION OF THE
SHORTEST
DIRECTION
VPOS
WR
0 ~ 100
0 ~ 100
When the input mode is D-SUB.
SIZE (DVI-D, D-SUB[RGB])
WIDE(#)
WR
1~3
1~3
1: WIDE, 2: NORMAL, 3: Dot by Dot
SIZE (HDMI, D-SUB[COMPONENT],
D-SUB[VIDEO])
WIDE(#)
WR
1、4、5
1、4、5
1: WIDE, 4: NORMAL, 5: Dot by Dot
RESET
ARST
W
1
: ‘14/September
Click on the first or last page to see other PN-Y325 service manuals if exist.