PN-V601 (serv.man21). New service tool and firmware - Sharp Monitor Technical Bulletin (repair manual). Page 2

Read Sharp PN-V601 (serv.man21) Technical Bulletin online

IDP 2013 06 07 
 
Date of Issue: 
24
th
 June 2013      
         
Classification: 
White 
IDP TECHNICAL BULLETIN
 
Page 2 of 3 
 
 
Sharp Electronics (UK) Limited 
Reference 
– PNF-A190
 
Revision  - 1 
 
White 
– Carry out as required 
Yellow 
– Carry out as required and whenever the unit comes in for service 
 Red 
– Carry out on all units   
2) When setting the target of the control by the command using IDLK and IDSL 
commands, if the applicable monitor does not exist, no response will be 
returned but only in this case, the command to cancel the target of the control 
will not be accepted for following 90 seconds. 
  On PN-V601, 36-Multi (6 x 6), when turning ON the signal output device of 
ASTRODESIGN that is specialized for the users who use the HDMI connection, in 
very rare cases, the signal resolution would become 4095 x 16. 
 
From January 2012 (Firmware V1.09) 
  When using DVI / HDMI the screen disappears for a moment and then reappears. 
  If the monitors were powered ON after 2~5 seconds delay when connected to 
certain devices (Matrix switcher DXP 44 DVI PRO manufactured by Extron) and 
PN-V601 with DVI Daisy chain and then inputting the content without HDCP, the 
screens on the monitors (From the monitor-ID2) other than the monitor-ID1 
connected with the Daisy chain would be frozen with the noise like a sandstorm 
being displayed. 
  When connecting a PC (HP Z600/Z400 + Graphic Board NVIDIA Quadro FX 1800) 
and 3 units of PN-E601
’s with HDMI and then starting up the PC, the image was 
displayed in a reduced size.  
  When power ON under low temperature, the operation of the power supply PWB 
became unstable. This caused the phenomenon that the backlights would not be lit 
or a part of the areas would be dark. For the improvement of this phenomenon, the 
default value of PWM FREQUENCY which is the setting of PWM frequency for 
dimming the brightness has been changed from AUTO (Max 3KHz) to HIGH 
(800Hz locked). 
 
From February 2012 (Firmware V1.11) 
  When power ON under low temperature, the operation of the power supply PWB 
became unstable. This caused the phenomenon that the backlights would not be lit 
or a part of the areas would be dark. In the case that all power supply PWBs are 
the ones that the measures have been taken, the maximum frequency when the 
setting is AUTO will be set to 3KHz and in the cases other than above the 
maximum frequency will be set to 800Hz. 
 
From March 2013 (Firmware V1.15) 
  When a particular PN-V601 and PN-ZB02 (Interface extension board) are 
combined, it takes about 2 minutes to turn on backlight after power on. Then a 
back light error occurs after turning on the backlight.  
  "BOTU" sound may have occurred when the power supply is turned OFF, the off-
sequence of voice amplifier was changed. 
 
Page of 3
Display