PN-U423/U473/U553 Installation Guidelines <Rev1.1> March 2014 
-This model is only for internal use. Please avoid  weather and direct sunlight when installing. They cause  breakdown and degradation. 
-Humidity condition for IDP 
 Range of humidity condition for IDP : 
From 20% to 80%(no condensation) 
-Dew condensation and/or liquid drops will cause the breakdown of the circuit and/or LCD panel. 
  Please install LCD away from condensation and liquid drops. 
-About dew condensation 
  The back cabinet of the product is plate. So dew condensation  occurs easily. 
-the environment which has high possibility of condensation                               
The place where temperature is generally low but has frequent warm air flow.                                                                          
(Example : the place in front of the vents of radiators. When the radiator is turn on in a cold winter morning, condensation occurs.) 
 Near the sea, lake, mountain and so on where humidity is high 
-the environment which has high possibility of water drops                         
 
“Semi-outdoor” place where strong winded-rain(typhoon) could potentially reach the monitor. The place which is below the pipes inside 
the ceiling. (When installing in these places, countermeasures should be taken to avoid water drops to reach the monitors. For example, 
covering the LCD monitor with box. In such a case, consideration should be given for direction of vent.) 
-caution for the wind of the typhoon 
 Please install so that you can remove the influence from the wind.  
-caution for salt damage 
 Please hold counsel with us in advance when installing near the sea where salt damage may occur. 
-caution for sulfide 
 
Please don’t install near the hot spring and volcano where there may occur the influence from sulfide. 
-caution for organic gas and flammable gas  
 
Please don’t install  the place where there may be organic gas and flammable gas.  
Precautions for installation location, dew condensation, water drops and salt damage 
About installation location, dew condensation, water drops and salt damage 
Air-breathing 
from below 
Exhausting the 
air to back 