PN-S655 (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 21

Read Sharp PN-S655 (serv.man5) User Guide / Operation Manual online

21
E
Your monitor can be connected to a LAN allowing you to 
control it from a PC on the LAN. 
You can also configure the monitor to send e-mail notification 
when it has a problem. 
The connection requires a commercially available LAN cable 
(UTP cable, Category 5, straight through).
Hub 
LAN terminal 
LAN cable (commercially available, straight) 
Network (LAN) 
TIPS
•  You must assign an IP address to the monitor by following 
the procedures in “Settings to connect to a LAN”. (See the 
description on the right.)
•  Your PC must be installed with Internet Explorer (version 6.0 
or later). 
•   To control the monitor via LAN, set RS-232C/LAN SELECT 
to LAN. (See page 7.)
•  You cannot use RS-232C and LAN control simultaneously. 
Controlling the Monitor with a PC (LAN)
Settings to connect to a LAN
Set the monitor’s IP address and subnet mask to match the 
settings of your LAN. 
These settings can be made on either the monitor or a PC 
connected to the monitor.
The settings depend on the configuration of your LAN. Ask 
your LAN administrator for details. 
■ To set on the monitor
Set RS-232C/LAN SELECT on the SETUP menu to LAN, and 
then set the LAN SETUP options. (See page 7.)
After setting each item, select SET and press 
MENU
.
DHCP CLIENT
If your LAN has a DHCP server and you wish to obtain an 
address automatically, change this setting to ON. 
To set the address manually, set this to OFF. 
IP ADDRESS
If the DHCP CLIENT is set to OFF, specify an IP address. 
Press 
 or 
  to select items, and press 
 or 
 to 
change the values.
SUBNET MASK
If the DHCP CLIENT is set to OFF, specify the subnet mask. 
Press 
 or 
  to select items, and press 
 or 
 to 
change the values.
DEFAULT GATEWAY
If the DHCP CLIENT is set to OFF, specify the default 
gateway. 
If you are not using a gateway, specify “0.0.0.0”. 
Press 
 or 
  to select items, and press 
 or 
 to 
change the values.
RESET
Resets the values of the LAN settings to the factory preset 
values. 
Select ON and then press 
MENU
.
Page of 30
Display

Click on the first or last page to see other PN-S655 (serv.man5) service manuals if exist.