Read Sharp PN-R903 Handy Guide online

Precautions for dust
Precautions for using anti-dust display
About dust
-Fundamentally, LCD monitor is designed for indoor usage.
When it is being used outdoor or at dusty places such as
-when using the anti-dust display(enclosure), please remove 
the 
d t ith filt
-When it is being used outdoor, or at dusty places, such as 
railway station or close to the traffic, the solutions against dust 
must be considered.
Precautions for using the filter
(1)it is possible to prolong the filter life by 
using two filter and exchanging the fine 
dust with filter.
-If the anti-dust solutions are not being considered ->
The dust will enter into the LCD panel through the gaps and will
The effect of dust
(2)it may raise the internal temperature for a display when using the 
filter, because of raising the air resistance.
Please reduce the air resistance by increasing the area of filter, etc.
g
g g
screen pre-filter.
The dust will enter into the LCD panel through the gaps and will 
cause the distorted image (see example below), and will break 
down in the end.
(3)when making the enclosure, it needs the caution whether the fan 
air-breathe or exhaust the air.
Intake air fan:
The pressure in the enclosure is higher than out of enclosure
The pressure in the enclosure is higher than out of enclosure. 
Therefore, dust does not break in the housing. It is limited the size of 
intake vent. And it is difficult to suck in much air(when using in dusty 
area).
Exhaust air fan:
The dust enters into the LCD panel 
and causes the distorted  image.
AS
Countermeasure against dust
C
t
l t l
l d
l
The pressure in the housing is lower than out of enclosure. 
Therefore, dust breaks in the housing. It has much size of intake 
vent. And it is easy to control  the temperature(when using in less 
dusty area and severe temperature requirements).
-Create a completely sealed enclosure.
-The completely sealed enclosure shut off dust so it is 
advantageous for installation in locations with excessive 
amounts of dust, outdoor, and  that may occur in salt.
to keep the performance, please clean the filter regularly
PN-R903 Installation Guidelines <Rev1.0> February 2013
CONFIDENTIAL
5
-You will need to be a combination of countermeasure against 
thermal, such as the heat exchanger and the air conditioner.
Intake air fan
Exhaust air fan