PN-R603/R703 Installation Guidelines <Rev1.0> February 2013 
CONFIDENTIAL 
-In particular, when monitors are installed one above the 
other, the temperature raise of topside monitor cause of the 
exhaust heat from downside monitor. 
 
Regarding the countermeasure against temperature, Please 
keep the clearance in P.3. 
 
In fact, when installing multi-display, it is hard to keep the 
clearance in P.3. Therefore, please keep the temperature 
requirements to do the countermeasures as below. 
1) Reduce the surrounding temperature(using an air-
conditioner) 
2)Get down the brightness(when a brightness gets down, a 
power consumption and heat gets down) 
3)Keep much clearance between the monitors 
4)Flow the air forcibly between monitors 
  It is effective to use the spot cooler or fan in the back(when 
the monitors catch the wind, they are easily attached the 
dust). 
About thermal influence 
About expansion 
 
 
Black tape 
Please be sure the wind as much as 
possible so as to pass through, not 
choked . 
Precautions for space between displays 
(multi-display) 
If the gap between displays spoils appearance (e. g. back of 
the display can been seen through), please hide it by affixing 
black tape at the rear. 
Note: DO NOT seal the “exhalation fan and intake-nozzle” by 
black tape. 
Please attach the tape before connecting cables. 
It is necessary to check the tape periodically to make sure 
that the tape isn’t detached from the display as time goes by. 
Hiding the gap between the bezels 
 
 
 
 
 
 
The cabinet and frame of the information display is expanded 
due to heat. 
It is necessary to reserve enough space when aligning 
multiple displays. 
If  the space between displays is small, the weight  is loaded 
to LCD panel by heat expansion. 
It is necessary to increase the gap when Installing more large 
display. (Standard about 5 mm) 