PN-L802B (serv.man3). Training Material - Sharp Monitor Handy Guide. Page 45

Read Sharp PN-L802B (serv.man3) Handy Guide online

 
 
 
 
 
Troubleshooting 
Service Menu 2 
 
 
The “HARDWARE CHECK” is a good way to 
determine problems with the Power Supply, 
Backlights, and over- temperature conditions. 
 
If a SYS PW1 – PW5 are indicating 
NG
, then 
replace the Delta DC Power Supply PWB. 
 
If the BACKLIGHT is indicating 
NG, 
replace 
the Delta DC Power Supply  PWB. 
 
When a THML 1-3 is 
NG, 
the unit may have 
been installed incorrectly with limited air 
flow, or has a defective THML component.  
Move set to an open air condition to test.  
Replace PC/IF PWB if the problem persists 
which indicates a bad THML. 
 
Please note:  THML’s are simple Thermistor.   
The PNL702B only has 1 Thermistor and it is 
located on the I/F PWB, however, the 
software will display all three as the same.  
 
42 
Page of 48