Read Sharp PN-L703B (serv.man3) Service Manual online
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 50
24. NONDISCLOSURE SCREEN OF CONTROLLING THE MONITOR WITH PC (LAN)
The screens described in this chapter are not open to the public.
24-1. SERVICE MENU
For the service menu, the following web access screen is
provided.
This screen is displayed when the following URL is accessed with
a web browser.
http://<IP Address>/service.cgi
On this screen, the following item can be set.
Item
Set value range, remark
COMMAND
When [Send] button is clicked, the RS-232C command
entered to the edit box by the user is sent to this
machine.
The response of the command is displayed in the
lower section of the edit box.
SYSTEM LOG
The system log file of this machine is obtained.
When the anchor is clicked, the file download dialogue
of the browser is displayed.
Follow the instructions of the dialogue.
TEMPERATURE
LOG
The temperature log file of this machine is obtained.
When the anchor is clicked, the file download dialogue
of the browser is displayed. Follow the instructions of
the dialogue.
Display when a command is sent from the edit box of
“COMMAND”
When the command “POWR????” which reads the power status
is sent.
Example of the display when “1” (Power ON status) is sent back
from the display.