PN-L602B (serv.man18). Change of capacitors (C7817 and C7818) on the Power Supply - Sharp Monitor Technical Bulletin (repair manual)

pn-l602b (serv.man18) technical bulletin
Model
PN-L602B (serv.man18)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
364.28 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Monitor / Change of capacitors (C7817 and C7818) on the Power Supply
File
pn-l602b-sm18.pdf
Date

Read Sharp PN-L602B (serv.man18) Technical Bulletin online

IDP 2015 01 05 
 
Date of Issue:  16
th
 January 2015 
         
Classification: 
White 
IDP TECHNICAL BULLETIN
 
Page 1 of 2 
 
 
Sharp Electronics (UK) Limited 
Reference 
– PNF-A357
 
Revision  - 1 
 
White 
– Carry out as required 
Yellow 
– Carry out as required and whenever the unit comes in for service 
 Red 
– Carry out on all units   
 
MODELS 
PNE602 
PNL602 
 
 
 
 
 
 
 
REASON 
We have changed the Capacitors (C7817 and C7818) on the Power Supply part 
during production. 
 
If the capacitors (C7817, C7818) in the power supply unit fail and the power output is 
an abnormal condition, you may experience the following issues: 
  Power can be turned ON but the screen remains black and nothing is displayed. 
  When turning the power ON, the screen is just faintly displayed. 
  The picture occasionally disappears during use. 
 
ACTION 
If you require the Power Supply, use the part number below. 
 
 
 
This part was changed from September 2014 production. 
 
 
 
Confirmation of the production date 
Using the information provided below, you can identify the production date using the 
serial number: 
  The first digit is the year. The last digit is the month. 
Note - The last digit goes from 0-9, X=October, Y=November and Z=December. 
 
Reference Number  Description 
Model Number  PART NUMBER 
PRICE CODE 
Delta DC PSU  As above 
RDENC1024MPPZ 
BZ 
IDP 2015 01 05 
 
Date of Issue:  16
th
 January 2015 
         
Classification: 
White 
IDP TECHNICAL BULLETIN
 
Page 2 of 2 
 
 
Sharp Electronics (UK) Limited 
Reference 
– PNF-A357
 
Revision  - 1 
 
White 
– Carry out as required 
Yellow 
– Carry out as required and whenever the unit comes in for service 
 Red 
– Carry out on all units   
 
 
Page of 2
Display

Download Sharp PN-L602B (serv.man18) Technical Bulletin

Here you can read online and download Sharp PN-L602B (serv.man18) Technical Bulletin in PDF. PN-L602B (serv.man18) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp PN-L602B (serv.man18) Monitor. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.