Controlling the Monitor with a PC
You can control this monitor from a PC via RS-232C (COM 
port) on the PC.
You can also connect multiple monitors via a daisy chain by 
using a PC. By assigning ID numbers to each monitor (see 
page 26), you can make input mode selection/adjustment or 
can check the status of a specific monitor.
PC connection
One-to-one connection with a PC
Connect with RS-232C straight cable between the PC’s COM 
port (RS-232C connector) and the RS-232C input terminal on 
the monitor.
RS-232C straight cable 
(commercially available)
To COM port
PC
RS-232C input terminal
Daisy chain connection…
Advanced operation
Connect with RS-232C straight cable between the PC’s COM 
port (RS-232C connector) and the RS-232C input terminal on 
the first monitor. 
Next, connect RS-232C straight cable to the first monitor’s 
RS-232C output terminal and to the second monitor’s 
RS-232C input terminal. Connect in the same way to the third 
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the 
length of the cable used and the surrounding environment.)
RS-232C straight cables 
(commercially available)
First monitor
Second monitor
PC
To COM port
RS-232C 
output terminal
RS-232C 
input terminal
Communication conditions
Set the RS-232C communication settings on the PC to match 
the monitor’s communication settings as follows:
Baud rate
9600 bps
Stop bit
1 bit
Data length
8 bits
Flow control
None
Parity bit
None
Communication procedure
Command format
When a command is sent from the PC to the monitor, the 
monitor operates according to the received command and 
sends a response message to the PC.
C1
C2
C3
C4
P1
P2
P3
P4
Return code
Command field 
(4 prescribed 
alphanumerical characters)
Parameter field 
(4 character string comprised of: 
0-9, +, -, space, ?)
 Example:  VOLM0030
 
VOLM     30
*  Be sure to input 4 characters for the parameter. Pad with 
spaces (“ ”) if necessary.  
(“   ” is a return code (0D
H
, 0A
H
 or 0D
H
))
Wrong  : VOLM30
Right  : VOLM     30
When inputting a negative value, specify a numerical value in 
three digits.
 Example: AUTR-009
Do not use spaces for MPOS, DATE, and SC01 through 
SC08. Specify parameters using a specified number of 
characters.
 Example: MPOS010097
If a command has “R” listed for “DIRECTION” in the 
“RS-232C command table” on page 29, the current value can 
be returned by using “?” as the parameter.
 Example:
VOLM ? ? ? ?
From PC to monitor (How much 
is current volume setting?)
30
From monitor to PC (Current 
volume setting: 30)
*  If an ID number (see page 26) has been assigned 
(For example, ID number = 1)
VOLM 
?
From PC to monitor
30   001
From monitor to PC