PN-G655E (serv.man3) - Sharp Monitor Service Manual (repair manual). Page 24

Read Sharp PN-G655E (serv.man3) Service Manual online

PN-G655E
CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 16
 Initialization/Functional Restriction Setting (FUNCTION) menu
 Others
Function
Command
Direc-
tion
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0
-
A D J U S T M E N T
LOCK
ALCK
WR
0-2
0-2
0: OFF
o
OSD DISPLAY
LOSD
WR
0-1
0-1
0: ON, 1: OFF
o
LED
OFLD
WR
0-1
0-1
0: ON, 1: OFF
o
Function
Command
Direc-
tion
Parameter
Reply
Control/Response contents
*
SCREEN SIZE (PC)
WIDE
WR
1-5
1-5
1: WIDE, 2: NORMAL, 3: DotbyDot, 4: ZOOM1,
5: ZOOM2
o
SCREEN SIZE (AV)
WIDE
WR
1-5
1-5
1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL,
5: DotbyDot
o
VOLUME
VOLM
WR
0-31
0-31
o
MUTE
MUTE
WR
0-1
0-1
0: OFF, 1: ON
-
INFORMATION MODEL
INF1
R
Value
o
SERIAL NO
SRNO
R
Value
o
BRIGHT
VLMP
WR
0-31
0-31
Brightness
o
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
o
1
Internal temperature abnormal (Standby mode)
o
2
Internal temperature abnormal (Temperature is nor-
mal now, but it was abnormal during operation.)
o
3
Internal temperature abnormal
(Brightness of the backlight decreases.)
o
4
Temperature sensor abnormal
o
TEMPERATURE ACQUISITION
ERRT
R
Value
Temperature at temperature sensors 1 through 3 are
returned in the following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
o
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
o
R
0
No detectable error has occurred
1
Standby mode by POWER button
2
Main power “OFF” by the main power switch
3
Standby mode by RS-232C
4
Waiting mode by No Signal
(Incl: VESA DPMS/DMPM)
6
Standby mode by abnormal temperature
8
Standby mode by SCHEDULE setting
Page of 79