PN-E802 (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 42

Read Sharp PN-E802 (serv.man5) User Guide / Operation Manual online

42
E
■ To set from a PC
When the monitor is connected to a PC, LAN settings can be 
configured via PC. 
Set up process
(1) Connect your monitor to a PC
(2) Specify the PC’s IP address
(3) Configure the monitor’s LAN settings
(1) Connecting your monitor to a PC
Connect a commercially available crossover LAN cable 
(UPT cable, Category 5) to the LAN  port on the PC and this 
monitor.
LAN cable 
(commercially available, crossover)
To LAN terminal
PC
LAN terminal
(2) Specifying the PC’s IP address
To configure the monitor’s LAN settings, you must temporarily 
change the settings on the PC. 
This explanation is based on Windows 7.
1.  Log on to the PC with an administrator account. 
2.  Click [Start], and then click “Control Panel”.
3.  Click “View network status and tasks” in “Network and 
Internet”.
In “Classic View”, click “Network and Sharing Center”.
4.  Click “Local Area Connection” and then “Properties”.
5.  Click “Internet Protocol Version 4 (TCP/IPv4)” and then 
“Properties”.
6.  Make a note of the current IP address, subnet mask, and 
default gateway settings. 
Make sure you write this information now as you will 
be changing the IP address, subnet mask, and default 
gateway settings back to these settings afterwards. 
7.  Temporarily change the IP address and subnet mask. 
To access the monitor as it is shipped from the factory, set 
as follows. 
•  IP Address: 192.168.150.1
•  Subnet Mask: 255.255.255.0
•  Default Gateway: (leave blank)
8.  Click [OK] and then reboot the PC.
TIPS
•  This monitor is factory preset as shown below.  
(When DHCP CLIENT is set to OFF)
  IP Address 
: 192.168.150.2
  Subnet Mask 
: 255.255.255.0
  Default Gateway  : 0.0.0.0
(3) Configuring the monitor’s LAN settings
Access the monitor using Internet Explorer. 
Controlling the monitor
1.  Turn the power ON to the monitor.
2.  Set RS-232C/LAN SELECT on the SETUP menu to LAN. 
3. Set DHCP CLIENT to OFF in LAN SETUP on the SETUP 
menu.
PC operation
4.  Launch Internet Explorer, in the “Address” box type 
“http://192.168.150.2/” and press the Enter key. 
You will be prompted to enter a user name and password. 
5.  Leave the user name and password boxes blank and click 
[OK]. 
Controlling the Monitor with a PC (LAN)
Page of 56