PN-E602 (serv.man3) - Sharp Monitor Service Manual (repair manual). Page 117

Read Sharp PN-E602 (serv.man3) Service Manual online

CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-E702/E602 DISASSEMBLY AND ASSEMBLY
 6 – 19
13. KEY PWB
1 ) Remove the key PWB fixing plate. Lift the key PWB and remove the flat cable.
CAUTION
NOTE FOR ASSEMBLY
n
Put the key PWB so that it is fitted with the hole in the IR filter.
n
Slide the key PWB fixing plate so that it is engaged with the rib.
n
Slightly pull the flat cable to check that it is connected securely.
Key PWB Hold board
Key PWB
IR filter
Rib
Rib
Front bezel cover BTM
Flat cable
Page of 127
Display

Click on the first or last page to see other PN-E602 (serv.man3) service manuals if exist.