Read Sharp PN-E602 (serv.man3) Service Manual online
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-E702/E602 DISASSEMBLY AND ASSEMBLY
6 – 19
13. KEY PWB
1 ) Remove the key PWB fixing plate. Lift the key PWB and remove the flat cable.
CAUTION
NOTE FOR ASSEMBLY
n
Put the key PWB so that it is fitted with the hole in the IR filter.
n
Slide the key PWB fixing plate so that it is engaged with the rib.
n
Slightly pull the flat cable to check that it is connected securely.
Key PWB Hold board
Key PWB
IR filter
Rib
Rib
Front bezel cover BTM
Flat cable