PN-E521 (serv.man3) - Sharp Monitor Service Manual (repair manual). Page 122

Read Sharp PN-E521 (serv.man3) Service Manual online

CHAPTER 7. PN-E601/E521 DISASSEMBLY AND ASSEMBLY
PN-E601 PN-E601/E521 DISASSEMBLY AND ASSEMBLY
 7 – 14
■ PN-E521
1 ) Unscrew 4pcs of Screw (M3 x 6 (Silver)).  Remove the Speaker angle R .
CAUTION
NOTE FOR ASSEMBLY
n
Tighten the screw in the sequence of 
1, 2, 3,and 4.
SCREW TIGHTENING TORQUE
n
Screw: 0.7 - 0.9N •m
2 ) Disconnect 2 connectors.  Unscrew 4pcs of Screw (M3 x 6s/sw (Silver)).  Slide the Inverter unit (L) and Inverter unit (S) towards the center of
LCD module to remove them.
CAUTION
NOTE FOR ASSEMBLY
n
Slide and insert the Inverter unit (L) and Inverter unit (S) into the lamp sockets.
n
Align the boss with the cut beside the screwing point.
n
After installing the inverter unit, form the relay harness so that it should be 3mm high or less from the connector's connecting point.
SCREW TIGHTENING TORQUE
n
0.7 - 0.9N •m
1
4
2
3
A
B
Lamp socket
Connector x 2
Relay harness
Screw x 4
Boss
Cut
Connector's connecting point
3mm high 
or less
Page of 127