PN-E421 (serv.man5) - Sharp Monitor User Guide / Operation Manual. Page 17

Read Sharp PN-E421 (serv.man5) User Guide / Operation Manual online

17
E
You can return the settings to their factory-preset values and 
restrict operations.
1.  After pressing   for about 5 seconds, press   ,   , 
 , and   in that order.
OFF
UNLOCKED
ON
ON
LED
OFF
MONITOR
FUNCTION 
1/1 
ALL RESET
ADJUSTMENT LOCK
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
CONTROLLER  INPUT
END…[MENU]
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings. 
Press   , select ALL RESET, and then press  .
After initialization, turn the main power switch off and 
then back on.
When the PN-ZB01 (optional) is attached, press  , 
select the resetting method, and then press  .
ALL RESET1 ....Resets all the settings to the factory 
default settings.
ALL RESET2 ....Returns all settings to the factory default 
settings except for the following items: 
LAN SETUP, RS-232C/LAN SELECT, 
ID No. SET, BAUD RATE, NETWORK, 
MAIL, SERVICE & SUPPORT, and 
SNMP (See page 11, and pages 33 to 
36.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
1.........Disables all operations other than turning power 
on/off and FUNCTION.
2.........Only the FUNCTION operation is enabled. 
Disables all operations other than FUNCTION (not 
even power on/off).
RS-232C
(RS-232C/LAN when the PN-ZB01 (optional) is 
attached)
Specifies whether to allow control via RS-232C or LAN 
(see pages 18 and 29).
OSD DISPLAY
Hides/shows menus. 
The FUNCTION screen cannot be hidden.
LED
Specifies whether to light the power LED.
OFF cannot be selected when STANDBY MODE is LOW 
POWER.
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
TEMPERATURE ALERT
Selects the notification method for an abnormal 
temperature.
OFF .............. Do not notify about an abnormal 
temperature.
OSD & LED .. When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately and the screen 
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the 
power LED flashes in red and the screen 
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the 
power LED flashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears, 
change the setting accordingly.
CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears, 
change the setting accordingly.
3.  Press   to return to the normal screen.
TIPS
•  When both abnormal temperature and hardware error are 
detected, the hardware error notification overrides.
Page of 43