PN-70TA3 (serv.man12) - Sharp Monitor User Guide / Operation Manual. Page 62

Read Sharp PN-70TA3 (serv.man12) User Guide / Operation Manual online

62
E
Commands for setting of the GAMMA user data
Function
Command Direction
Parameter
Reply
Control/Response contents
RED GAMMA DATA TRANSFER
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
GREEN GAMMA DATA TRANSFER
UGGW
W
BLUE GAMMA DATA TRANSFER
UGBW
W
RED GAMMA DATA READ
UGRR
W
1-16 xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
GREEN GAMMA DATA READ
UGGR
W
1-16
BLUE GAMMA DATA READ
UGBR
W
1-16
USER DATA INITIALIZE
UGRS
W
0
Initialize the user data.
USER DATA SAVE
UGSV
W
0
Save the user data in the monitor.
To transfer the GAMMA user data
Use the user data transfer commands (UGRW, UGGW and UGBW). For each of the R, G and B colors, divide the total 512 
pieces of user data into 16 blocks, and transfer 32 pieces of data with each command.
C1 C2 C3 C4 P1 P2 P3 P4
… S1 S2
Command field Block number (01 to 16) Data field Checksum field
  Example: To transfer the data of block 1 (0 to 31 levels) 
of red (R) data
UGRW01000000010002 … 0031C0
Command Block number 32 pieces of data
Checksum
One piece of data consists
of 4 digits.
*  If data is less than 4 digits, add a “0” (zero) to make it 4 digits.
*  The checksum field is the character string (ASCII) data of lower-order one byte which indicates the sum of the block number 
and 32 pieces of data in hexadecimal (0 to F).
Saving the GAMMA user data
Use the user data save command (UGSV) to save the transferred user data in the monitor.
If the data is not saved, it will be cleared when:
•  The main power switch is off
•  STANDBY MODE is LOW POWER and the monitor enters standby mode
Activating the GAMMA user data
To activate the transferred user data, select USER for GAMMA in the PICTURE menu, or send the corresponding control 
command.
Checking the GAMMA user data
Use the user data read commands (UGRR, UGGR and UGBR) to return 512 pieces of user data for each of the R, G and B 
colors. Divide the data into 16 blocks and return 32 pieces of data with each command. The value to be returned is not the value 
stored in the monitor, but the value in the temporary memory for display. (These values are the same when the user data save 
command (UGSV) above has been sent.)
TIPS
•  The user data is not initialized by RESET of the PICTURE menu. To initialize the user data, use ALL RESET of the 
FUNCTION menu. 
The GAMMA user data initialize command (UGRS) allows the initialization of the user data only.