CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 9
3. PC OPERATION
3-1. COMMUNICATION PROCEDURE
Basic operation
<Command format>
When a command is sent from the PC to the monitor, the monitor oper-
ates according to the received command, and sends a response mes-
sage to the PC.
Example: VOLM0030
POWR
30 (“ 
” indicates a space.)
*Be sure to input 4 characters for the parameter. 
Pad with spaces if necessary.
Wrong :  VOLM30 [Enter]
Right   :  VOLM
30 [Enter]
(“
” indicates a space. [Enter] is the return code
(0DH, 0AH or 0DH).)
If a command has “R” listed for “DIRECTION” in the “RS-232C Com-
mand table”, the current value can be returned by using “?” as the
parameter.
Example :
1. If an ID number has not been set:
VOLM????
1 From PC to monitor 
(How much is current volume setting?)
30
1 From monitor to PC (Current volume setting: 30)
2. If an ID number has been assigned (For example, ID number 
=
 1)
VOLM
?
1 From PC to monitor (“ ” indicates a space.)
30
001
1 From monitor to PC (“ ” indicates a space.)
<Response code format>
[SIZE]
(about 5 
seconds)
4
[b]
4
[d ]
4
[c]
4
[e ]
FUNCTION
ALL RESET
Returns all settings to their factory preset values. After initializa-
tion (reset), turn the main power switch off and then back on.
ADJUSTMENT LOCK
LOCKED/UNLOCKED
Specifies whether to lock settings such as ADJUSTMENT and
WHITE BALANCE.
While locked, the remote control unit cannot perform operations
other than turning power on/off (POWER button) and displaying
the FUNCTION 1 screen.
LOCKED
:  Locks the setting.
UNLOCKED : Unlocks the setting.
OSD DISPLAY
ON/OFF
Hides/shows menus. The FUNCTION 1 screen cannot be hidden.
ON : Displays the menus.
OFF : Hides the menus.
LED
ON/OFF
Specifies whether to light LEDs.
ON : Lights LEDs.
OFF : Does not light LEDs.
RS-232C
LOCKED/UNLOCKED
Specifies whether to allow control via RS-232C.
LOCKED
: Disables control via RS232C.
UNLOCKED
: Enables control via RS-232C.
BUTTON
ITEM
ADJUSTMENT
DESCRIPTION
C1
C2
C3
C4
P1
P2
P3
P4
Return code
Command field
(4 prescribed
alphanumerical
characters)
Parameter field
(4 character string
comprised of:
0-9, 
+
, space
, ?)
 When a command has been executed correctly
This is returned when execution
of the command is finished.
 When a command has not been executed correctly 
*
* This is returned when there is 
no such command, or when 
the command cannot be 
used in the current state of 
the monitor (Example: When 
“ADJUSTMENT” is used (a 
command which is effective 
when the input mode is 
“ANALOG”), while video is 
displayed (the input mode is 
“VIDEO”)).
* If there is a bad connection
between the PC and moni-
tor, or if communication has 
not been established, nothing 
is returned (not even ERR).
 If execution of the command is taking some time
With some commands, “WAIT” 
is returned as a return value. 
Wait for a moment, and OK or 
ERR will be returned. New 
commands cannot be received 
during this time, even if they are 
sent.
 If RS-232C is locked
If RS-232C control has been
locked with the operation lock,
LOC KED is  retur ned as  th e
returned value.
O
K
Return code (0D
H
, 0A
H
)
R
R
E
Return code (0D
H
, 0A
H
)
I
W
T
A
Return code (0D
H
, 0A
H
)
E
C
D
K
O
L