PN-465E (serv.man19). Low Temperature start-up fails - Sharp Monitor Technical Bulletin (repair manual)

pn-465e (serv.man19) technical bulletin
Model
PN-465E (serv.man19)
Pages
4 Few pages! See other manuals at the bottom of the first or last page.
Size
768.16 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Monitor / Low Temperature start-up fails
File
pn-465e-sm19.pdf
Date

Read Sharp PN-465E (serv.man19) Technical Bulletin online

IDP 2010 09 01 
 
Date of Issue:    25
th
 September 2010 
         
Classification: 
White 
LCD MONITOR DISPLAY TECHNICAL BULLETIN
 
Page 1 of 4 
 
 
Sharp Electronics (UK) Limited 
Reference – PNF-A012/018
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
 
MODELS
 
PN-465E PN-G655E 
 
 
 
 
 
 
 
 
 
SYMPTOM
  Low Temperature start up failure on units produced before October 2007. 
 
CAUSE
 
Reset IC timing errors 
 
ACTION 
Using the circuit and layout given below check and replace if required C477 and R461. 
 
Please mark both the IF PWB and chassis to indicate modification has been actioned. 
 
 
REF NO DESCRIPTION PART 
NUMBER PRICE 
CODE 
R461 
C477 
470kΩ Resistor 
1µF Capacitor 
VRSRCY2AY474JN 
VCKYRY1AB105KN 
AA 
AA 
 
 
 
 
 
 
 
 
IDP 2010 09 01 
 
Date of Issue:    25
th
 September 2010 
         
Classification: 
White 
LCD MONITOR DISPLAY TECHNICAL BULLETIN
 
Page 2 of 4 
 
 
Sharp Electronics (UK) Limited 
Reference – PNF-A012/018
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
 
Figure 1: Location of R461 and C477. 
IDP 2010 09 01 
 
Date of Issue:    25
th
 September 2010 
         
Classification: 
White 
LCD MONITOR DISPLAY TECHNICAL BULLETIN
 
Page 3 of 4 
 
 
Sharp Electronics (UK) Limited 
Reference – PNF-A012/018
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
Figure 2: Circuit Location of R461 and C477. 
IDP 2010 09 01 
 
Date of Issue:    25
th
 September 2010 
         
Classification: 
White 
LCD MONITOR DISPLAY TECHNICAL BULLETIN
 
Page 4 of 4 
 
 
Sharp Electronics (UK) Limited 
Reference – PNF-A012/018
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
 
Figure 3 and 4 location of marks to identify modification 
Page of 4
Display

Download Sharp PN-465E (serv.man19) Technical Bulletin

Here you can read online and download Sharp PN-465E (serv.man19) Technical Bulletin in PDF. PN-465E (serv.man19) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp PN-465E (serv.man19) Monitor. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.