LL-T1820 (serv.man5). Troubleshooting - Sharp Monitor Service Manual (repair manual). Page 3

Read Sharp LL-T1820 (serv.man5) Service Manual online

PC-UM10M
LL-T1820-H/B   TROUBLE SHOOTING
4 – 3
(No)
(No)
(No)
(Yes)
(Yes)
(No)
(No)
(Yes)
(No)
(Yes)
(Yes)
(No)
(Yes)
(No)
(Yes)
(No)
(Yes)
(Yes)
(Yes)
(No)
(No)
(No)
(Yes)
(Yes)
(Yes)
(Yes)
(No)
(Yes)
(No)
(No)
(No)
(Yes)
(No)
(No)
(Yes)
(No)
(Yes)
(Yes)
Check DC+5V power supply line (AV5) , 
POWER_CTL1 signal, and circuits around 
Q808.
Check DC+5V power supply line (PV5) , 
POWER_CTL3 signal, and circuits around 
Q800.
Check the power supply unit and cable and 
their connections, and POWER_CTL1 
Check DC+2.5V power supply line (DV25), 
POWER_CTL1 signal, and circuits around 
IC800.
Check DC+12V power supply line (LCDV), 
POWER_CTL2 signal, and circuits around 
Q800.
Check OSC500 and clock circuit around 
IC502.
Clock (R517) and DE (R515) signal outputs 
are normal?
ADJUSTMENT and MODE SELECT are set 
properly?
Signal waveform of test terminal LD510 is 
normal?
ADJUSTMENT and MODE SELECT are set 
properly?
Adjust according to "screen adjustment 
procedure".
Adjust according to "screen adjustment 
procedure".
Check circuits around IC300, IC301, and 
IC401.
Check circuits around IC701, and CN700 
and LCD module.
Check DC+5V power supply line (DV5A), 
POWER_CTL1 signal, and circuits around 
Q808.
Test terminals LD419, LD515, and LD700 are 
DC+3.3V?
Signal waveform of test terminal LD500 is 
normal?
Test terminals LD416, LD417, and LD418 are 
DC+3.3V?
8th pin of Q808 is DC+5V?
Test terminal LD809 is DC+5V?
Test terminal LD810 is DC+5V?
Test terminal LD807 is DC+12V?
Test terminal LD509 is DC+2.5V?
TP801 is DC+12.0V?
36th pin of LC601 is in H level (DC+5V)?
The entire LCD screen is white?
The entire LCD is black?
The size of LCD screen is abnormal?
 LCD screen jitters or flickers?
Check circuits around IC400.
Check circuits around IC402.
Check circuits around IC601.
Test terminal of LD701 is DC+12V?
Check circuits around X600 and IC601.
Check circuits around IC501.
Check circuits around CN700.
Check circuits around IC401.
Check circuits around IC501.
4
Page of 4
Display

Click on the first or last page to see other LL-T1820 (serv.man5) service manuals if exist.