CHAPTER 2. REMOVING LCD MODULE
Procedure:
Disassembly
1. Remove the DC cover and RGB cover.
2. Remove the 2 screws in 
.
3. Remove the 6 screws in 
.
4. Remove the 2 screws in 
 and remove the VGA cable (loosen
another two screws.
5. Remove the 9 screws in 
 and remove the rear cabinet.
6. Remove the switch connector and the screw in 
.
7. Remove the 4 screws in 
 and remove the 8 screws in 
.
8. Remove the 2 screws in 
.
9. Remove the 2 CCFT connectors.
10. Remove the shielding plate from the front cabinet.
Reassembly
1. Reassemble the parts in the reverse order of disassembly steps (1
- 10).
·
Use caution to prevent the cables from getting caught in the
cabinet when reinstalling the parts.
·
Pay attention to tightening torque:
Screws of 
: 6 kg-cm
Screws of 
: 4 kg-cm
CHAPTER 3. CONNECTION, ADJUSTMENT, OPERATION AND FUNCTIONS
Connecting procedure
Note:
·
Make sure that both the monitor and computer are turned off before connecting or disconnecting the cord or
cable.
·
When connecting or disconnecting the cord and cable, make sure to hold their plug, not the cord or cable.
·
Make sure to use the AC adapter supplied with the monitor. (Sharp ADP-0011-A)
Proceed to the next page according to the installation method of the monitor.
1. In the case of using on desktop
·
1-1 The AC adapter is put outside
- - - 1-1 When the AC adapter is to be installed outside
·
1-2 The AC adapter is housed in the monitor - - - 1-2 When the AC adapter is installed on the stand
2. In the case of installing on the
arm or stand
- - - - - - 2. Cautions to be taken when installing a VESA standard compatible arm. (reference)