LL-T155A (serv.man2). LLT155A - Sharp Monitor Service Manual (repair manual). Page 15

Read Sharp LL-T155A (serv.man2) Service Manual online

CHAPTER5. TRIMING AND PROCESSING LEAD WIRES
Step 1
Put the CCFT cable and LCD cable into shield plate bushings to
prevent them from getting caught when installing the shield plate.
(Figs. 1 and 2)
Put the CCFT cable at the back of the LCD module to prevent it
from getting caught when installing the LCD module.
Step 2
Use caution to prevent the power supply cable and switch cable
from getting caught when installing arm rear cover (Fig. 3).
Use caution to prevent the power supply and switch cable from
getting caught when installing the base metal.
CCFT cable
Inverter cable
Power supply cable
Switch cable
LCD cable
Fig. 1
Fig. 2
Power supply cable
Power supply cable
Switch cable
Fig. 3
Fig. 4