LL-P202V. Training Material - Sharp Monitor Handy Guide. Page 83

Read Sharp LL-P202V Handy Guide online

Temperature error observation
 
The thermistor in the monitor observes the temperature. When the temperature becomes high, the error is displayed by the LED and the 
OSD message. 
 
- How to display the high temperature error 
1. Temperature error OSD is displayed on the monitor. 
2. The LED lights up in order of RED -> GREEN -> RED -
> GREEN ….. 
From the Setup > Others > TEMPERATURE ALERT, it is possible to select the notification method for an abnormal temperature. 
- Protection operation 
1. Decrease the brightness 
When the high temperature error is detected, decrease the brightness (brightness becomes 0 in the Brightness menu) and reduce the 
increase of the temperature. 
2. Power OFF 
When the high temperature error is detected again with decreasing the brightness, the main power is turned OFF. 
- Record to the Log 
When the temperature error is detected, the following items are recorded to the log. 
1. Accumulated operation time (Hour) 
2. Temperature when the temperature error is occurred (Degrees C) 
The thermistor AD on the Main I/F PWB is observed per one minute. When the detected temperature is over the threshold value 
continuosly three times, the state of the thermistor AD is judged whether it is in the correct state or not. 
This operation is done with the monitor being in the operating state (the backlight lights) and is not done with the backlight being OFF. 
- How to operate under the high temperature error 
The monitor is operated in the following sequence under the high temperature error. 
Page of 86
Display