LL-H1813 - Sharp Monitor Service Manual (repair manual). Page 15

Read Sharp LL-H1813 Service Manual online

PC-UM10M
LL-H1813   TROUBLE SHOOTING
4 – 1
CHAPTER 4. TROUBLE SHOOTING
(Yes)
(Yes)
(Yes)
(Yes)
(Yes)
(Yes)
Green LED comes on when the power button is 
pressed?
The screen is displayed properly in each video 
mode?
AC cable is connected to the power supply 
unit?
Input signal port is the one to which analog 
signal cable is connected?
Test terminals LD416, LD417, and LD418 are 
DC+3.3V?
Test terminal LD628 changes its level when 
POWER switch is turned on and off?
Press INPUT key to switch over to the 
correct input signal port.
Check the power supply unit and power 
supply cable and their connections.
Check DC+5V power supply line (DV5A) 
and POWER_CTL1 signal and circuits  
around 0808.
Check DC+5V power supply line (AV5) and 
POWER_CTL1 signal and circuits around 
0808.
Check MAINPW signal and areas around 
CN800.
Remove the analog signal cable. After a short 
while time, the LED color changes form green 
to orange. 
(Yes)
(Yes)
(No)
(No)
(Yes)
(Yes)
(No)
(No)
(No)
(No)
(Yes)
(Yes)
(No)
(No)
(No)
(No)
(No)
(Yes)
(No)
(Yes)
(No)
(Yes)
(Yes)
(No)
(No)
(No)
Perform  1
B/L is lit?
No error.
Check AC cable connection.
Check power supply unit switch.
Check circuits around IC600. 
Check circuits around IC400.
Check RESET circuit around IC602.
Check IC601 and clock circuit around X600.
Check SW100 and circuits around IC100.
The power supply unit is switched on?
SW100 is on 1st pin side?
Test terminal LD805 is DC+5V?
8th pin of 0808 is DC+5V? 
4th pin of IC602 is in H level (DC+5 V)?
Test terminal LD809 is DC+5V?
C610-side terminal signal of X600 is normal?
Test terminal LD634 is DC+3.3V?
1
Perform  2
Perform  3
Perform  4
Page of 36