R-98STMA (serv.man8). Test Procedures - Sharp Home Appliance Service Manual (repair manual). Page 3

Read Sharp R-98STMA (serv.man8) Service Manual online

R98STMAA
8 – 3
[7] G: THERMAL CUT-OUT TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the thermal cut-out. Then using an ohmmeter, make a continuity test across the two terminals as described
in the below.
If incorrect readings are obtained, replace the thermal cut-out.
An open circuit thermal cut-out (MG) indicates that the magnetron has overheated, this may be due to resistricted ventilation, cooling fan failure.
An open circuit thermal cut-out (GRILL) indicates that the oven cavity has overheated, this may be due to no load operation.
An open circuit thermal cut-out (CONV.) indicates that the convection fan winding has overheated, this may be due to resistricted ventilation or locked
cooling fan or locked convection fan motor.
CARRY OUT 4R CHECKS.
[8] H: MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two terminals as described in the table below.
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.
[9] I: NOISE FILTER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the noise filter. Using an ohmmeter, check
between the terminals as described in the following table. 
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS.
[10] J: BLOWN FUSE 20A
CARRY OUT 3D CHECKS.
If the fuse 20A is blown, there is a shorts or grounds in electrical parts or wire harness. Check them and replace the defective parts or repair the wire
harness.
CARRY OUT 4R CHECKS.
CAUTION: Only replace fuse with the correct value replacement.
[11] K: BLOWN FUSE F8A (NOISE FILTER)
CARRY OUT 3D CHECKS.
1. If the fuse F8A is blown when the door is opened, check the monitored latch switch SW1 and monitor switch.
2. If the fuse F8A is blown by incorrect door switching replace the defective switch(es) and the noise filter.
Table: Thermal Cut-out Test
Parts Name
Temperature of “ON” condition 
(closed circuit).
Temperature of “OFF” condition 
(open circuit).
Indication of ohmmeter (When room 
temperature is approx. 20
°C.)
Thermal cut-out 125
°C
This is not resetable type.
Above 125
°C
Closed circuit
Thermal cut-out 170
°C (GRILL)
Cuts back in at 155
°C.
Above 170
°C
Closed circuit
Thermal cut-out 170
°C (CONV.)
Cuts back in at 155
°C.
Above 170
°C
Closed circuit
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately  398.9 
Ω
Turntable 
motor
RMOTDA255WRZZ
Approximately   14.5 k
Ω
RMOTDA189WRE0
Approximately   12.0 k
Ω
Convection fan motor
Approximately 183.7 k
Ω
Dumper 
motor
RMOTDA257WRZ1
Approximately   14.5 k
Ω
RMOTDA257WRZZ
Approximately   14.5 k
Ω
RMOTDA191WRE0
Approximately   11.0 k
Ω
MEASURING POINT 
INDICATION OF OHMMETER
Between N and L 
Approx. 680 k
Ω
Between terminal N and WHITE 
Short circuit
Between terminal L and RED 
Short circuit
F8A
20A
WHT
RED
R1
R2
N
Cx
Cy
L
L
L
L (min) Cx ± 20% Cy ± 20%
1.0mH
0.22 uF
4700pF
Page of 5