R-98STMA (serv.man11). Component Replacement And Adjustment Procedure - Sharp Home Appliance Service Manual (repair manual). Page 4

Read Sharp R-98STMA (serv.man11) Service Manual online

R98STMAA
11 – 4
13.Remove the seven (7) screws holding the convection duct to the
oven cavity back plate from inside of the oven cavity.
14.Lift up the convection duct and release the three (3) tabs of the
oven cavity back plate from the convection duct.
15.Now, the convection unit assembly is free.
2. CONVECTION HEATING ELEMENT REMOVAL
1. Remove the convection unit assembly refer to the “CONVECTION
UNIT ASSEMBLY REMOVAL”.
2. Remove the two (2) screws holding the convection heating element
to the convection duct.
3. Remove the one (1) screw holding the convection heater angle to
the convection duct.
4. Remove the one (1) screw holding the convection heater angle and
the air separate angle D to the convection duct.
5. Remove the one (1) screw holding the convection heater angle A to
the convection duct.
6. Remove the convection heating element from the convection duct.
7. Now, the convection heating element is free.
3. CONVECTION MOTOR REMOVAL
1. Remove the convection unit assembly refer to the “CONVECTION
UNIT ASSEMBLY REMOVAL”.
2. Remove the one (1) nut and washer from the convection motor
shaft.
3. Remove the convection fan from the convection motor shaft.
4. Remove the pipe from the convection motor shaft. 
5. Remove the two (2) screws holding the convection motor angle to
the convection duct.
6. Remove the cooling fan from the convection motor shaft.
7. Remove the two (2) screws holding the convection motor to the
convection motor angle.
8. Remove the one (1) ring from the convection motor shaft.
9. Now, the convection motor is free.
[10] POSITIVE LOCK CONNECTOR REMOVAL
1. CARRY OUT 3D CHECKS.
2. Push the lever of positive lock
 connector.
3. Pull down on the positive lock
 connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
 CONNEC-
TORS TO THE TERMINALS, CONNECT THE POSITIVE
LOCK
 SO THAT THE LEVER FACES YOU.
Figure C-3. Positive lock
, connector
[11] OVEN LAMP SOCKET REMOVAL
1. CARRY OUT 3D CHECKS.
2. Remove the wire leads as Positive lock
 connector removal above.
3. Lift up the oven lamp from its retaining clips by pushing the tab of
the air intake duct.
4. Now, the oven lamp is free.
Figure C-4. Oven lamp
[12] POWER SUPPLY CORD REPLACEMENT
1. REMOVAL
1. CARRY OUT 3D CHECKS.
2. Remove the one (1) screw holding the green/yellow wire to the
back plate.
3. Disconnect the leads of the power supply cord from the noise filter,
referring to the Figure C-5(a).
4. Release the power supply cord from the rear cabinet.
5. Now, the power supply cord is free.
Figure C-5 (a) Replacement of Power Supply Cord
Terminal
Push
Pull down
1
2
Lever
Positive lock¨
connector
Lock
Socket
Bulb
Power supply
cord
Back plate
Blue wire
Brown wire
Green/
Yellow wire
Noise filter
WHIT
RED
F2
F1
TP
N
L
TL
Page of 7
Display

Click on the first or last page to see other R-98STMA (serv.man11) service manuals if exist.