R-962M - Sharp Home Appliance Service Manual (repair manual). Page 13

Read Sharp R-962M Service Manual online

R-962M - 13
Pin No.
Signal
I/O
Description
During cooking
L
H
20 msec.
20 msec.
H : GND
L (-5V)
24
INT0
IN
Signal to synchronized LSI with commercial power source
frequency(50Hz).
This is basic timing for time processing of LSI.
25
P41
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G8 line key on matrix is touched.
26
P40
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G7 line key on matrix is touched.
27
P77
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G6 line key on matrix is touched.
28
P76
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G5 line key on matrix is touched.
29
P75
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G4 line key on matrix is touched.
30
P74
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G3 line key on matrix is touched.
31
P73
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G2 line key on matrix is touched.
32
P72
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G1 line key on matrix is touched.
33
P71
OUT
Oven lamp and turntable motor driving signal(Square Waveform : 50Hz).
To turn on and off shut-off relay
(RY6). The square waveform
voltage is delivered to the relay
(RY6) driving circuit.
34
P70
IN
Connected to VC.
35
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied.
Temporarily set to "L" level the moment power is applied, at this time the LSI
is reset. Thereafter set at "H" level.
36
P81
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook
relay (RY2). In 100%
operation, the signals hold "L"
level during microwave
cooking and "H" level while
not cooking. In other cooking
modes (70%, 50%, 30%,
10%) the signal turns to "H"
level and "L" level in
repetition according to the
power level.
  
DESCRIPTION OF LSI
LSI(IZA963DR)
The I/O signal of the LSI(IZA963DR) are detailed in the following table.
ON/OFF time ratio in Micro
cooking
(a. 32second time base)
ON/OFF time ratio in Micro
cooking
(a. 48second time base)
MICRO
ON
OFF
COOK
100%
32 sec.
0 sec.
70%
24 sec.
8 sec.
50%
18 sec. 14 sec.
30%
12 sec. 20 sec.
10%
6 sec. 26 sec.
MICRO
ON
OFF
COOK
100%
48 sec.
0 sec.
70%
36 sec. 12 sec.
50%
26 sec. 22 sec.
30%
16 sec. 32 sec.
10%
8 sec. 40 sec.