R-899SL (serv.man7). Test Procedures - Sharp Home Appliance Service Manual (repair manual). Page 3

Read Sharp R-899SL (serv.man7) Service Manual online

R899(WH)
8 – 3
If incorrect readings are obtained, replace the thermal cut-out.
An open circuit thermal cut-out (MG) indicates that the magnetron has overheated, this may be due to resistricted ventilation, cooling fan failure.
An open circuit thermal cut-out (OVEN) indicates that the oven cavity has overheated, this may be due to no load operation, or excessive heat / fire
inside the oven.
CARRY OUT 4R CHECKS.
[8] H: MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two terminals as described in the table below.
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.
[9] I: NOISE FILTER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the noise filter. Using an ohmmeter, check
between the terminals as described in the following table. 
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS.
[10] J: BLOWN FUSE 20A
CARRY OUT 3D CHECKS.
If the fuse 20A is blown, there is a shorts or grounds in electrical parts or wire harness. Check them and replace the defective parts or repair the wire
harness.
CARRY OUT 4R CHECKS.
CAUTION: Only replace fuse with the correct value replacement.
[11] K: BLOWN FUSE F8A
CARRY OUT 3D CHECKS.
1. If the fuse F8A is blown when the door is opened, check the monitored latch switch and monitor switch.
2. If the fuse F8A is blown by incorrect door switching replace the defective switch(es) and the noise filter (fuse F8A).
3. If the fuse F8A is blown, there could be shorts in the asymmetric rectifier or there is a ground in wire harness. A short in the asymmetric rectifier
may be occurred due to short or ground in H.V. rectifier, magnetron, high voltage transformer or H.V. wire. Check them and replace the defective
parts or repair the wire harness.
CARRY OUT 4R CHECKS.
[12] L: GRILL HEATING ELEMENTS (TOP) AND BOTTOM HEATING ELEMENT TEST
CARRY OUT 3D CHECKS.
Before carrying out the following tests make sure the heating element is cool completely. 
1. Resistance of heater.
Disconnect the wire leads to the heating element to be tested. Using ohmmeter with low resistance range. Check the resistance across the termi-
nals of the heating element as described in the following table.
Table: Thermal Cut-out Test
Parts Name
Temperature of “ON” condition 
(closed circuit).
Temperature of “OFF” condition 
(open circuit).
Indication of ohmmeter (When room 
temperature is approx. 20
°C.)
Thermal cut-out 125
°C
This is not resetable type.
Above 125
°C
Closed circuit
Thermal cut-out 145
°C
Bellow  115
°C.
Above 145
°C
Closed circuit
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately   399
Ω
Turntable motor
Approximately 14.7k
Ω
Convection fan motor
Approximately  288k
Ω
MEASURING POINT 
INDICATION OF OHMMETER
Between N and L 
Approx. 680 k
Ω
Between terminal N and WHITE 
Short circuit
Between terminal L and RED 
Short circuit
F8A
20A
WHT
RED
R1
R2
N
Cx
Cy
L
L
L
L (min) Cx ± 20% Cy ± 20%
R1
R2
1.0mH
0.22 uF
4700pF 10 M
680k
Page of 5