R-895M (serv.man15). Complete - Sharp Home Appliance Service Manual (repair manual). Page 4

Read Sharp R-895M (serv.man15) Service Manual online

R-895M - 4
PRODUCT DESCRIPTION
SPECIFICATION
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts / 50 Hertz / Single phase, 3 wire earthed
Power Consumption
Microwave cooking
1.50 kW  Approx. 6.5 A
Convection cooking
1.91 kW  Approx. 8.0 A
Top Grill mode ...................... 1.25 kW
Approx. 5.2 A
Grill cooking
Bottom Grill mode ................. 0.70 kW
Approx. 2.9 A
Top and Bottom  mode ......... 1.90 kW
Approx. 7.9 A
Micro and Top Grill ............... 2.70 kW
Approx. 11.5 A
Dual cooking Micro and Bottom Grill .......... 2.15 kW
Approx. 9.2 A
Micro and Convection ........... 2.16 kW
Approx. 9.3 A
Power Output
900 W nominal of RF microwave energy (measured by method of IEC 60705)
Operating fequency 2450 MHz
Top Grill  heating element Power Output
1200 W
Bottom heating element Power Output
650 W
Case Dimensions
Width 520 mm
Height 309 mm (including foot)
Depth 482 mm
Cooking Cavity Dimensions
Width  353 mm
Height 207 mm
Depth 357 mm
Turntable diameter
325 mm
Control Complement
Touch Control System
Clock (1:00 - 12:59) / Timer (0 - 99 minutes 90 sec.)
Microwave Power for Variable Cooking
 Repetition Rate;
100 (HIGH) ....................... Full power throughout the cooking time
70 (MEDIUM HIGH) .........................  approx. 70% of FULL Power
50 (MEDIUM) ...................................  approx. 50% of FULL Power
30 (MEDIUM LOW) ..........................  approx. 30% of FULL Power
10 (LOW) .........................................  approx. 10% of FULL Power
Convection temperature control range:
   250˚C, 230˚C, 220˚C, 200˚C, 180˚C, 160˚C, 130˚C, 100˚C, 70˚C and 40˚C
TIME keys, BREAKFAST key, PIZZA key, EXPRESS COOK keys
EXPRESS DEFROST keys, MEAL IN ONE keys
POWER LEVEL key, GRILL key, DUAL CONV./GRILL key
CONV. (˚C) key, LESS/MORE keys, WEIGHT keys
INFO key, STOP/CLEAR key, START/AUTO MINUTE key
KITCHEN TIMER/CLOCK SET key
Net Weight
Approx. 19 kg
GENERAL INFORMATION
WARNING
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
As part of our policy of continuous improvement, we reserve the right to
alter design and specifications without notice
Page of 43
Display