R-874 (serv.man3). Control pannel assembly, component replacement procedure and leakage measurement - Sharp Home Appliance Service Manual (repair manual). Page 4

Read Sharp R-874 (serv.man3) Service Manual online

R-874M - 21
LSI(IXA094DR)
The I/O signal of the LSI(IXA094DR) are detailed in the following table.
  DESCRIPTION OF LSI
Pin No.
Signal
I/O
Description
Power output
ON time
OFF time
100 %
48 sec.
0 sec.
90 %
44 sec.
4 sec.
80 %
40 sec.
8 sec.
70 %
36 sec.
12 sec.
60 %
32 sec.
16 sec.
50 %
26 sec.
22 sec.
40 %
22 sec.
26 sec.
30 %
16 sec.
32 sec.
20 %
12 sec.
36 sec.
10 %
8 sec.
40 sec.
ON
OFF
During
cooking
L
GND
H.
(Convection or dual cooking)
ON
OFF
During cooking or for awhile after convection, 
grill (top and bottom grill ) or dual. 
L
GND
H.
38
XIN
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XOUT terminal.
39
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
40
VSS
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
41
P27
OUT
Bottom heating element driving signal.
To turn on and off the relay (RY4). "L"
level during grill cooking, convection
cooking or dual cooking, "H" level
otherwise.
The heater relay turns on and off within
a 48 second time base in accordance
with the special program in LSI.
42
P26
OUT
Convection motor driving signal.
To turn on and off shut-off relay(RY7). "L"
level during convection or dual cooking "H"
level otherwise. (Relay RY7 does not turn on
at preheating mode.)
43
P25
OUT
Fan motor driving signal.
To turn on and off the fan motor relay RY6.  "L"
level during cooking, or for a while after
convection, grill (top and bottom grill) or dual
cooking. "H" level otherwise.
44
P24
OUT
Terminal not used.
45
P23
OUT
Touch control transformer driving signal.
To turn on and off the shut off relay (RY5). If the oven has not been used for more
than 3 minutes, the relay RY5 will be turned off. The relay RY5 will be turned on
when the oven door is opened and closed.
46-48
P22-P20
OUT
Terminal not used.
49-50
P17-P16
IN
Terminal to change functions according to the model.
51-80
SEG39-SEG10
OUT
Segment data signal.
Connected to LCD.
The relation between signals are as follows:
LSI signal (Pin No.)
LCD (Pin No.)
LSI signal (Pin No.) LCD (Pin No.)
SEG 0 (90) .................... SEG39 (51)
SEG21 (69) ................. SEG19 (19)
SEG 1 (89) .................... SEG38 (50)
SEG22 (68) ................. SEG18 (18)
SEG 2 (88) .................... SEG37 (49)
SEG23 (67) ................. SEG17 (17)
SEG 3 (87) .................... SEG36 (48)
SEG24 (66) ................. SEG16 (16)
SEG 4 (86) .................... SEG35 (47)
SEG25 (65) ................. SEG15 (15)
SEG 5 (85) .................... SEG34 (46)
SEG26 (64) ................. SEG14 (14)
SEG 6 (84) .................... SEG33 (45)
SEG27 (63) ................. SEG13 (13)
SEG 7 (83) .................... SEG32 (44)
SEG28 (62) ................. SEG12 (12)
SEG 8 (82) .................... SEG31 (43)
SEG29 (61) ................. SEG11 (11)
SEG10 (80) ................... SEG30 (30)
SEG30 (60) ................. SEG10 (10)
SEG11 (79) ................... SEG29 (29)
SEG31 (59) ................... SEG 9 ( 9)
SEG12 (78) ................... SEG28 (28)
SEG32 (58) ................... SEG 8 ( 8)
SEG13 (77) ................... SEG27 (27)
SEG33 (57) ................... SEG 7 ( 7)
SEG14 (76) ................... SEG26 (26)
SEG34 (56) ................... SEG 6 ( 6)
SEG15 (75) ................... SEG25 (25)
SEG35 (55) ................... SEG 5 ( 5)
SEG16 (74) ................... SEG24 (24)
SEG36 (54) ................... SEG 4 ( 4)
SEG17 (73) ................... SEG23 (23)
SEG37 (53) ................... SEG 3 ( 3)
SEG18 (72) ................... SEG22 (22)
SEG38 (52) ................... SEG 2 ( 2)
SEG19 (71) ................... SEG21 (21)
SEG39 (51) ................... SEG 1 ( 1)
SEG20 (70) ................... SEG20 (20)
R-874 S/MANUAL
11/7/01, 10:59 am
21
Page of 13
Display

Click on the first or last page to see other R-874 (serv.man3) service manuals if exist.