R-84ST (serv.man6). Complete - Sharp Home Appliance Service Manual (repair manual). Page 12

Read Sharp R-84ST (serv.man6) Service Manual online

R-84STM - 12
TOUCH CONTROL / DESCRIPTION OF LSI
LSI(IXA094DR)
The I/O signal of the LSI(IXA094DR) are detailed in the following table.
Pin No.
Signal
I/O
Description
ON/OFF time ratio in Micro
cooking
(a. 32second time base)
ON/OFF time ratio in Micro
cooking
(a. 48second time base)
MICRO
ON
OFF
COOK
100%
32 sec.
0 sec.
70%
24 sec.
8 sec.
50%
18 sec. 14 sec.
30%
12 sec. 20 sec.
10%
6 sec. 26 sec.
MICRO
ON
OFF
COOK
100%
48 sec.
0 sec.
70%
36 sec. 12 sec.
50%
26 sec. 22 sec.
30%
16 sec. 32 sec.
10%
8 sec. 40 sec.
Power output
ON time
OFF time
100 %
48 sec.
0 sec.
90 %
44 sec.
4 sec.
80 %
40 sec.
8 sec.
70 %
36 sec.
12 sec.
60 %
32 sec.
16 sec.
50 %
26 sec.
22 sec.
40 %
22 sec.
26 sec.
30 %
16 sec.
32 sec.
20 %
12 sec.
36 sec.
10 %
8 sec.
40 sec.
During cooking
L
H
20 msec.
26
P40
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G7 line key on matrix is touched.
27
P77
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G6 line key on matrix is touched.
28
P76
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G5 line key on matrix is touched.
29
P75
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G4 line key on matrix is touched.
30
P74
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G3 line key on matrix is touched.
31
P73
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G2 line key on matrix is touched.
32
P72
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P44 - P47
terminal while one of G1 line key on matrix is touched.
33
P71
OUT
Oven lamp and turntable motor driving signal(Square Waveform : 50Hz).
To turn on and off shut-off relay
(RY1). The square waveform voltage
is delivered to the relay (RY1) driving
circuit.
34
P70
IN
Connected to VC.
35
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied.
Temporarily set to "L" level the moment power is applied, at this time the LSI is
reset. Thereafter set at "H" level.
36
P81
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook
relay (RY2). In 100%
operation, the signals hold "L"
level during microwave
cooking and "H" level while not
cooking. In other cooking
modes (70%, 50%, 30%,
10%) the signal turns to "H"
level and "L" level in repetition
according to the power level.
37
P80
OUT
Grill (TOP) heating element driving signal.
To turn on and off the grill heating
element relay (RY3). "L" level
during grill cooking, convection
cooking or dual cooking, "H" level
otherwise. The heater relay turns
on and off within a 48 second time
base in accordance with the
special program in LSI.
Page of 30
Display

Click on the first or last page to see other R-84ST (serv.man6) service manuals if exist.