R-752M (serv.man2) - Sharp Home Appliance Service Manual (repair manual). Page 10

Read Sharp R-752M (serv.man2) Service Manual online

10
752M -
Figure C-4. Switches
Pin No.
Signal
I/O
Description
78
COM1
OUT
Common data signal.
Connected to LCD signal C2.
79
COM0
OUT
Common data signal.
Connected to LCD signal C1.
80
VL3
IN
Power source voltage input terminal.
Standard voltage for LCD.
DESCRIPTION OF LSI
LSI(IZA954DR)
The I/O signal of the LSI(IZA954DR) are detailed in the following table.
WARNING:
Before carrying out any work carry out 3D checks
1)
D
isconnect the supply.
2)
D
oor opened, and wedged open.
3)
D
ischarge high voltage capacitor.
RE-WIRING
Ensure the following:
1.
Wires must not touch:
a)
High voltage parts.
(Magnetron, high voltage transformer, high voltage capacitor and high voltage rectifier assembly)
b)
Parts that become hot.
(Heating elements, oven lamp, oven cavity magnetron and high voltage transformer)
c)
Sharp edges.
(Bottom plates, oven cavity, waveguide flange, chassis support and other metallic parts)
d)
Movable parts.
(Fan blade, any motor, switch, switch lever and open button)
2.
Positive lock connectors are fitted correctly.  Ensure the locking pin is located correctly.
3.
Wires are connected correctly as per pictorial diagram.
4.
No wire leads are trapped by the outer wrap.
MONITORED LATCH SWITCH, STOP SWITCH
AND MONITOR SWITCH REMOVAL
MONITOR SWITCH
STOP SWITCH
MONITORED
LATCH SWITCH
Tab
Post
Post
Post
Tab
Tab
1. CARRY OUT 3D CHECKS.
2. Remove the control panel assembly referring to
“CONTROL PANEL REMOVAL”.
3. Disconnect the leads from all switches.
4. Remove the two (2) screws holding the latch hook to the
oven cavity.
5. Remove the latch hook.
6. Push the retaining tab slightly and remove the switch.
COMPONENT REPLACEMENT AND ADJUSTMENT
WIRING / RE-WIRING
Page of 23
Display

Click on the first or last page to see other R-752M (serv.man2) service manuals if exist.