TEST PROCEDURES
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING BOARD (PWB) IS
OPEN
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on the PWB,
this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURANCE
CAUSE OR CORRECTION
1
The rated AC voltage is not present at
Check supply voltage and oven power cord.
POWER terminal of connector (CN-A).
2
The rated AC voltage is present at primary
Low voltage transformer or secondary circuit defective.
side of low voltage transformer.
Check and repair.
3
Only pattern at “a” is broken.
*Insert jumper wire J1 and solder.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
4
Pattern at “a” and “b” are broken.
*Insert the coil RCILF2003YAZZ between “c” and “d”.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
NOTE: *At the time of these repairs, make a visual
inspection of the varistor for burning damage
and examine the transformer with tester for
the presence of layer short-circuit (check
primary coil resistance). If any abnormal
condition is detected, replace the defective
parts.
CARRY OUT 4R CHECKS.
VRS1
a
b
c
d
D20
WH - 3
A
5
1
AC
CN - A
OL/FM
/TTM
(J1)
D21
RY1
Page of 24