R-4G75M (serv.man4). Section 3 Component replacement and adjustment procedure, MWO measurement (page 23-29) - Sharp Home Appliance Service Manual (repair manual). Page 5

Read Sharp R-4G75M (serv.man4) Service Manual online

27
R-4G75(W)M
R-4G75(B)M
DOOR FILM
Removal
1. Tear the door film from the door panel.
2. Now, the door film is free.
Installation
1. Put the adhesive tape on the backing film of the door film
as shown in Fig. 8.
2. Tear the backing film by pulling the adhesive tape.
3. Put the pasted side of the door film on the door panel.
Figure C-8. Door film
Door film
Backing film
Adhesive tape
CHOKE COVER REMOVAL
1. Insert an iron plate(thickness of about 0.5mm) or flat type
screw driver to the gap between the choke cover and
door panel as shown figure to free the engaged part. The
protect sheet may be used not to damage the door panel.
2. Lift up the choke cover, now choke cover is free.
FLAT TYPE
SCREW-DRIVER
PROTECT BY TAPE
FLAT TYPE
SCREW-DRIVER
DOOR
PANEL
CHOKE
COVER
Figure C-7. Choke Cover Removal