R-4G75M (serv.man3). Section 2 Test procedures, LSI table (page 8-22) - Sharp Home Appliance Service Manual (repair manual). Page 8

Read Sharp R-4G75M (serv.man3) Service Manual online

15
R-4G75(W)M
R-4G75(B)M
TEST PROCEDURES (CONT'D)
PROCEDURE
LETTER
COMPONENT TEST
Checking the initial sensor cooking condition
(1) The oven should be plugged in at least five minutes before sensor cooking.
(2) Room temperature should not exceed 95˚F(35˚C).
(3) The unit should not be installed in any area where heat and steam are generated. The unit should not
be installed, for example, next to a conventional surface unit. Refer to the "INSTALLATION Instructions"
.
(4) Exhaust vents are provided on the back of the unit for proper cooling and air flow in the cavity. To permit
adequate ventilation, be sure to install so as not to block these vents. There should be some space for
air circulation.
(5) Be sure the exterior of the cooking container and the interior of the oven are dry. Wipe off any moisture
with a dry cloth or paper towel.
(6) The Sensor works with food at normal storage temperature.For example, chicken pieces would be at
refrigerator temperature and canned soup at room temperature.
(7) Avoid using aerosol sprays or cleaning solvents near the oven while using Sensor settings. The sensor
will detect the vapor given of by the spray and turn off before food is properly cooked.
(8) After 25 minutes if the sensor has not detected the vapor of the food, ERROR will appear and the oven
will shut off.
Water load cooking test
Make sure the oven has been plugged in at least five minutes before checking sensor cook operation. The
cabinet should be installed and screws tightened.
(1) Fill approximately 200 milliliters (7.2 oz) of tap water in a 1000 milliliter measuring cup.
(2) Place the container on the center of tray in the oven cavity.
(3) Close the door.
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on
the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS
P
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING
BOARD(PWB) IS OPEN.
STEPS
OCCURANCE
CAUSE OR CORRECTION
  1
The rated AC voltage is not present at 
POWER terminal of CPU connector (CN-A)
Check supply voltage and oven power cord. Please use 
term "Low voltage transformer" when refering to 
transformer T1
  2 
The rated AC voltage is present at primary 
side of  low voltage transformer.
Low voltage transformer or secondary circuit  defective. 
Check and repair.
  3
Only pattern at "a" is broken.
*Insert jumper wire J1 and solder. (CARRY OUT 3D 
CHECKS BEFORE REPAIR)
  4
Pattern at "a" and "b" are broken.
*Insert the coil RCILF2003YAZZ between "c" and "d". 
(CARRY OUT 3D CHECKS BEFORE REPAIR) 
NOTE: At the time of these repairs, make a visual
inspection of the varistor for burning damage
and examine the transformer with tester for
the presence of layer short-circuit (check
primary coil resistance). If any abnormal
condition is detected, replace the defective
parts.
CARRY OUT 4R CHECKS
a
d
c
b
OL TTM FAN M
POWER
CN–A
(J1)
VRS1
RY1
D81
(R110)(J11)
(J10)
D82
RY2
17
1
3
5
Q
AH SENSOR TEST
Page of 15
Display