R-465 (serv.man3). Troubleshooting guide and test procedure - Sharp Home Appliance Service Manual (repair manual). Page 4

Read Sharp R-465 (serv.man3) Service Manual online

R-465(SL)
9
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT 4R CHECKS.
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the thermal cut-out. Then using an ohmmeter, make a
continuity test across the two terminals as described in the table below.
 CARRY OUT 4R CHECKS.
Table: Thermal cut-out Test
Temperature of "ON" condition
Temperature of  "OFF" condition
Indication ofohmmeter
Parts Name
(closed circuit) (˚C)
(open circuit) (˚C)
(When room temperature
 is approx. 20˚C)
Thermal cut-out 125˚C
This is not resetable type.
Above 125˚C
Closed circuit.
If incorrect readings are obtained, replace the thermal cut-out.
An open circuit thermal cut-out 125˚C (MG) indicates that the magnetron has overheated, this may
be due to resistricted ventilation, cooling fan failure or a fault condition within the magnetron or HV
circuit.
An open circuit thermal cut-out 125˚C (OVEN) indicates that the foods in the oven may catch fire, this
may  be due to over heating produced by improper setting of the cooking time or failure of the control
panel.
F
THERMAL CUT-OUT  TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the monitor resistor. Using an ohmmeter and set on a low range. Check
between the terminals of the monitor resistor.
The resistance of monitor resistor is approx.  0.8 ohms.
If incorrect readings are obtained, replace the monitor resistor.
 CARRY OUT 4R CHECKS.
G
MONITOR RESISTOR TEST
H
MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor.
Using an ohmmeter, check the resistance between the two terminals as described in the table below.
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately 400 
Turntable motor
Approximately 12 k
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS
CARRY OUT 3D CHECKS.
1. If the fuse F10A is blown, there could be shorts or ground in electrical parts or wire harness.
Check them and replace the defective parts or repair the wire harness.
2. If the fuse F10A is blown when the door is opened, check the 1st. interlock switch, relay RY1,
monitor switch and monitor resistor.
I
BLOWN FUSE  F10A
Page of 7
Display

Click on the first or last page to see other R-465 (serv.man3) service manuals if exist.